AS

Alessandro Stuart Savoia

info

Please Note

8 records found

Conference paper (2025) - Monica La Mura, Muhammad Usman Khan, Marta Saccher, Rob Van Schaijk, Alessandro Stuart Savoia
This work describes a method to estimate the mean collapse and snapback voltages of CMUT elements and their statistical distribution by extracting the voltage-dependent capacitance from fast dynamic excitation of the device, enabling fast analysis of fabrication-related intra-element and inter-element variability. While both voltage excitation and current excitation of the CMUT element provide comparable array-level results in terms of mean and deviation of positive and negative collapse and snapback voltages, it is demonstrated that improved detection of isolated collapse and snapback events is achieved through current-driven excitation, implementing charge-controlled actuation of the membranes. ...
Journal article (2025) - Andrada I. Velea, Raphael Panskus, Benedikt Szabo, Vera A.L. Oppelt, Lukas Holzapfel, Cyril B. Karuthedath, Abhilash T. Sebastian, Thomas Stieglitz, Alessandro S. Savoia, Vasiliki Giagka
Ultrasound (US) is a promising modality for wirelessly powering implantable devices, requiring encapsulated receivers to ensure long-term stability. Traditional hermetic packaging often limits acoustic transmission, making polymer-based encapsulation a more suitable alternative. This study investigates how implant-grade polymers, thermoplastic polyurethane (TPU), parylene-C, and medical-grade silicones (MED-1000 and MED2-4213), affect the receive performance of piezoelectric micromachined ultrasonic transducers (PMUTs). Simulations and measurements between 1 and 7 MHz show that all tested materials exhibit transmission coefficients above 94% at nanometer- and micrometer-scale thicknesses, confirming their acoustic transparency. The results show that although coated PMUTs are acoustically well matched with the surrounding water medium, the added mechanical load of the coating can hinder membrane motion and reduce the energy transferred to the PMUTs. Modeling and experimental data demonstrate that stiffer coatings, such as parylene-C, lead to a reduced sensitivity when similar thicknesses are used. Likewise, residual stress in materials like MED-1000 can also degrade the performance. These effects are not evident from acoustic transmission measurements alone, underscoring the need to assess both acoustic and mechanical properties when selecting encapsulation materials. In general, softer materials offer excellent acoustic performance for PMUT encapsulation, while stiffer materials must be applied in thinner layers to avoid impairing PMUT function. ...
Journal article (2024) - Marta Saccher, Alessandro Stuart Savoia, Rob Van Schaijk, Johan H. Klootwijk, Ronald Dekker
Capacitive micromachined ultrasonic transducers (CMUTs) offer several advantages over standard lead zirconate titanate (PZT) transducers, particularly for implantable devices. To eliminate their typical need for an external bias voltage, we embedded a charge storage layer in the dielectric. The objective of this study was to evaluate the performance of plasma-enhanced chemical vapor deposition (PECVD) Si3N4 and atomic layer deposition (ALD) Al2O3 as materials for the charge storage layer and two different dielectric layer thicknesses, focusing on their application as receivers in a wireless power transfer link. Capacitance-voltage (CV) measurements revealed that Si3N4 has a higher charge storage capacity compared to Al2O3. Additionally, a thicker dielectric layer between the bottom electrode and the charge storage layer (Bdiel) improved both charge trapping and retention, as assessed in dynamic accelerated lifetime transmit (TX)-mode tests. We then analyzed the power conversion performance of the fabricated CMUTs through both simulations and experiments. We performed extensive modeling based on an equivalent circuit derived from electrical impedance measurements of the fabricated CMUTs. The model was used to predict the power conversion efficiency under various conditions, including the charging field strength, the operating frequency, and parasitic series resistance. Power transfer experiments at 1- and 2.4-MHz recorded efficiencies exceeding 80% with an optimally matched load and up to 54% with a purely resistive load. Results confirmed that, with optimal load matching, the efficiency of different CMUT variants is comparable, indicating that the optimal variant should be selected based on additional criteria, such as charge retention time. ...
Conference paper (2024) - Muhammad Usman Khan, Monica La Mura, Marta Saccher, Rob Van Schaijk, Ronald Dekker, Alessandro Stuart Savoia
Estimation of the collapse (Vcol) and snapback (Vsb) voltages of Capacitive Micromachined Ultrasonic Transducers (CMUTs) is usually performed by extracting C-V curves from low frequency impedance measurements at different bias points. However, impedance analysis in several bias conditions is time-consuming, making this technique unsuitable for wafer-level testing. Additionally, prolonged exposure to high electric fields may lead to charge injection and trapping phenomena in the CMUT in-cavity insulation layers. This paper proposes an adjustment to the conventional impedance analysis technique aimed at enhancing estimation accuracy and introduces a novel technique for fast C-V assessment enabling rapid wafer-level characterization. Results from both techniques are compared, demonstrating the validity of the proposed approaches. ...
Conference paper (2023) - Alessandro S. Savoia, Domenico Giustiniano, Carlo Prelini, Marta Saccher, Amin Rashidi, Alberto Leotti, Vasiliki Giagka, Marco Ferrera
Micromachined Ultrasonic Transducers (MUTs) are being explored as power converters in wirelessly powered biomedical implants. This paper investigates the role of mechanical support properties in piezoelectric MUTs (PMUTs) on their power conversion efficiency. For this purpose, a finite element model (FEM) of a PMUT array was developed and integrated with an equivalent circuit model (ECM). The study considered different mechanical support scenarios, from rigidly clamped to completely free. These were numerically analyzed and validated by impedance measurements and acoustic power transfer experiments on PMUT prototypes. The results show that reducing the mass of the mechanical support increases the Q factor, leading to a significant improvement in power conversion efficiency, with an efficiency increase factor of 5.6x from the clamped to the free case. This approach can potentially enhance overall power conversion efficiency, reduce the need for matching networks, and enable miniaturization in ultrasonically powered implants. ...
Conference paper (2023) - Amin Rashidi, Marta Saccher, Cyril Baby Karuthedath, Abhilash Thanniyil Sebastian, Alessandro Stuart Savoia, Frederik Lavigne, Frederic Stubbe, Ronald Dekker, Vasiliki Giagka
Aluminum Nitride (AlN) Piezoelectric Micromachined Ultrasonic Transducers (PMUTs) are gaining interest for biomedical implant power due to biocompatibility and lowtemperature processing. However, due to the low piezoelectric coefficient of AlN PMUTs, storage capacitors are often used to accumulate ultrasonic power transferred over an extended time. The accumulated energy is then used to power a DC load, which leads to a long start-up time, and insufficient duty cycle for some applications. We present an ultrasonically powered system for biomedical implants capable of delivering mW-range instantaneous power to DC loads, without pre-storing it. The system features a 25 mm2 AlN PMUT, an inductive matching network, and an application-specific power management integrated circuit(ASIC). For an acoustic intensity of 360 mW/cm2 at the surface of the PMUT, an open-circuit voltage of 1.11 V and an aperture efficiency of 30.5 % are measured. Furthermore, by connecting a series-matching inductor to the PMUT, the highest-reported power delivered to the load (PDL) of 6.4 mW is measured over an optimal load of 7.6 Ω. Finally, together with the ASIC and at the intensity of 108 mW/cm2, our system delivers 1.04 mW DC power to a 3.3 kΩ load, which is over two orders of magnitude higher than the previously reported average DC power for AlN PMUTs. ...
Conference paper (2023) - Marta Saccher, Rob van Schaijk, Shinnosuke Kawasaki, Johan H. Klootwijk, Amin Rashidi, Vasiliki Giagka, Alessandro Stuart Savoia, Ronald Dekker
Capacitive Micromachined Ultrasound Transducers (CMUTs) have many advantages compared to other ultrasonic transducer technologies, especially for implantable devices. However, they require a high bias voltage for efficient operation. To eliminate the need for an external bias voltage, a charge storage layer can be embedded in the dielectric. This study aims to compare the performance of Si 3 N 4 and Al 2 O 3 when used as a charge storage layer. By measuring the shift in the C-V curve, Si 3 N 4 exhibits a larger shift than Al 2 O 3 , indicating a better charge-trapping capability. When using the pre-charged CMUTs as power receivers, the Si 3 N 4 version harvested up to 80 mW -only a few mW more than the Al 2 O 3 - with an efficiency of about 50 %. Accelerated Lifetime Tests predict a lifetime of about 7.8 and 1.2 years for Si 3 N 4 and Al 2 O 3 respectively. ...
Conference paper (2023) - Marta Saccher, Amin Rashidi, Alessandro Stuart Savoia, Vasiliki Giagka, Ronald Dekker
In the domain of ultrasonically powered biomedical implants, there is an increasing interest in cm-scale ultrasonic receivers (RX). However, when a single-element transducer is used as the RX transducer, an uneven phase distribution across the RX area can significantly reduce the harvestable power. In this paper, we investigate the impact of lateral and angular misalignment on the acoustic field phase distribution across the RX surface. We show that, for a single-element RX transducer, lateral misalignment has minimal effect on the harvestable power, whereas even small angular misalignments can cause a considerable reduction, especially for larger RX sizes. We present a potential solution that consists of subdividing a large RX transducer (e.g. 20 × 20mm2) into smaller elements, which significantly improves power transfer efficiency by taking advantage of the smaller phase variation across the surface of each element. The trade-offs between achieving a minimum acceptable power transfer efficiency and managing the increased complexity in packaging and matching circuitry are also discussed. ...