Current detection using a Josephson parametric upconverter

Journal Article (2020)
Author(s)

Felix Schmidt (Kavli institute of nanoscience Delft, TU Delft - QN/Steele Lab)

Daniel Bothner (TU Delft - QN/Steele Lab, Kavli institute of nanoscience Delft)

I. C. Corveira Rodrigues (Kavli institute of nanoscience Delft, TU Delft - QN/Steele Lab)

Mario Gely (TU Delft - QN/Steele Lab, Kavli institute of nanoscience Delft)

M.D. Jenkins Sanchez (Kavli institute of nanoscience Delft, TU Delft - QN/Steele Lab)

G.A. Steele (Kavli institute of nanoscience Delft, TU Delft - QN/Steele Lab)

Research Group
QN/Steele Lab
Copyright
© 2020 F.E. Schmidt, D. Bothner, I.C. Corveira Rodrigues, M.F. Gely, M.D. Jenkins Sanchez, G.A. Steele
DOI related publication
https://doi.org/10.1103/PhysRevApplied.14.024069
More Info
expand_more
Publication Year
2020
Language
English
Copyright
© 2020 F.E. Schmidt, D. Bothner, I.C. Corveira Rodrigues, M.F. Gely, M.D. Jenkins Sanchez, G.A. Steele
Research Group
QN/Steele Lab
Issue number
2
Volume number
14
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

We present the design, measurement, and analysis of a current sensor based on a process of Josephson parametric upconversion in a superconducting microwave cavity. When a coplanar waveguide is terminated with a nanobridge-constriction Josephson junction, we observe modulation sidebands from the cavity that enable highly sensitive frequency-multiplexed output of small currents for applications such as readout of transition-edge sensor arrays. We derive an analytical model to reproduce the measurements over a wide range of bias current, detuning, and input power. When the frequency of the cavity is tuned by more than 100 MHz with a dc current, our device achieves a minimum current sensitivity of 8.9pA/Hz. Extrapolating the results of our analytical model, we predict an improved device based on our platform, capable of achieving a sensitivity down to 50fA/Hz, or even lower if one can take advantage of parametric amplification in the Josephson cavity. Taking advantage of the Josephson architecture, our approach can provide higher sensitivity than kinetic inductance designs, and potentially enables detection of currents ultimately limited by quantum noise.

Files

License info not available