Design and Proof-of-Concept of a Matrix Transducer Array for Clamp-on Ultrasonic Flow Measurements

Journal Article (2022)
Author(s)

J.M. Massaad Mouawad (TU Delft - ImPhys/Medical Imaging)

P. L.M.J. van Neer (TU Delft - ImPhys/Medical Imaging)

Douwe Van van Willigen (TU Delft - Electronic Instrumentation)

E. Noothout (TU Delft - ImPhys/Medical Imaging)

N. de Jong (TU Delft - ImPhys/Medical Imaging)

M. A P Pertijs (TU Delft - Electronic Instrumentation)

M.D. Verweij (TU Delft - ImPhys/Medical Imaging)

Research Group
ImPhys/Medical Imaging
Copyright
© 2022 J.M. Massaad Mouawad, P.L.M.J. van Neer, D.M. van Willigen, E.C. Noothout, N. de Jong, M.A.P. Pertijs, M.D. Verweij
DOI related publication
https://doi.org/10.1109/TUFFC.2022.3186170
More Info
expand_more
Publication Year
2022
Language
English
Copyright
© 2022 J.M. Massaad Mouawad, P.L.M.J. van Neer, D.M. van Willigen, E.C. Noothout, N. de Jong, M.A.P. Pertijs, M.D. Verweij
Research Group
ImPhys/Medical Imaging
Issue number
8
Volume number
69
Pages (from-to)
2555-2568
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Common clamp-on ultrasonic flow meters consist of two single-element transducers placed on the pipe wall. Flow speed is measured noninvasively, i.e., without interrupting the flow and without perforating the pipe wall, which also minimizes safety risks and avoids pressure drops inside the pipe. However, before metering, the transducers have to be carefully positioned along the pipe axis to correctly align the acoustic beams and obtain a well-calibrated flowmeter. This process is done manually, is dependent on the properties of the pipe and the liquid, does not account for pipe imperfections, and becomes troublesome on pipelines with an intricate shape. Matrix transducer arrays are suitable to dynamically steer acoustic beams and realize self-alignment upon reception, without user input. In this work, the design of a broadband 37×17 matrix array (center frequency of 1 MHz) to perform clamp-on ultrasonic flow measurements over a wide range of liquids (c=1000-2000m/s, α≤1 dB/MHz · cm) and pipe sizes is presented. Three critical aspects were assessed: efficiency, electronic beam steering, and wave mode conversion in the pipe wall. A prototype of a proof-of-concept flowmeter consisting of two 36-element linear arrays (center frequency of 1.1 MHz) was fabricated and placed on a 1-mm-thick, 40-mm inner diameter stainless steel pipe in a custom-made flow loop filled with water. At resonance, simulated and measured efficiencies in water of the linear arrays compared well: 0.88 and 0.81 kPa/V, respectively. Mean flow measurements were achieved by electronic beam steering of the acoustic beams and using both compressional and shear waves generated in the pipe wall. Correlation coefficients of R2>0.99 between measured and reference flow speeds were obtained, thus showing the operational concept of an array-based clamp-on ultrasonic flowmeter.