Simulation-Aided Design of Tubular Polymeric Capsules for Self-Healing Concrete

Journal Article (2017)
Author(s)

Branko Šavija (TU Delft - Materials and Environment)

J. Feiteira (Universiteit Gent)

M. Araújo (Universiteit Gent)

S. Chatrabhuti (Université de Mons)

JM Raquez (Université de Mons)

K van Tittelboom (Universiteit Gent)

Elke Gruyaert (Universiteit Gent)

N de Belie (Universiteit Gent)

E. Schlangen (TU Delft - Materials and Environment)

Research Group
Materials and Environment
Copyright
© 2017 B. Šavija, J. Feiteira, M. Araújo, S. Chatrabhuti, JM Raquez, K van Tittelboom, Elke Gruyaert, N de Belie, E. Schlangen
DOI related publication
https://doi.org/10.3390/ma10010010
More Info
expand_more
Publication Year
2017
Language
English
Copyright
© 2017 B. Šavija, J. Feiteira, M. Araújo, S. Chatrabhuti, JM Raquez, K van Tittelboom, Elke Gruyaert, N de Belie, E. Schlangen
Research Group
Materials and Environment
Issue number
1
Volume number
10
Pages (from-to)
1-13
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Polymeric capsules can have an advantage over glass capsules used up to now as proof-of-concept carriers in self-healing concrete. They allow easier processing and afford the possibility to fine tune their mechanical properties. Out of the multiple requirements for capsules used in this context, the capability of rupturing when crossed by a crack in concrete of a typical size is one of the most relevant, as without it no healing agent is released into the crack. This study assessed the fitness of five types of polymeric capsules to fulfill this requirement by using a numerical model to screen the best performing ones and verifying their fitness with experimental methods. Capsules made of a specific type of poly(methyl methacrylate) (PMMA) were considered fit for the intended application, rupturing at average crack sizes of 69 and 128 m, respectively for a wall thickness of ~0.3 and ~0.7 mm. Thicker walls were considered unfit, as they ruptured for crack sizes much higher than 100 m. Other types of PMMA used and polylactic acid were equally unfit for the same reason. There was overall good fitting between model output and experimental results and an elongation at break of 1.5% is recommended regarding polymers for this application.