Effect of supernatant water level on As removal in biological rapid sand filters

Journal Article (2018)
Author(s)

Jink C. J. Gude (TU Delft - Sanitary Engineering)

Koen Joris (Pidpa Water Company, Antwerp)

Koen Huysman (Pidpa Water Company, Antwerp)

LC Rietveld (TU Delft - Sanitary Engineering)

D Van Halem (TU Delft - Sanitary Engineering)

Research Group
Sanitary Engineering
Copyright
© 2018 J.C.J. Gude, K. Joris, K. Huysman, L.C. Rietveld, D. van Halem
DOI related publication
https://doi.org/10.1016/j.wroa.2018.100013
More Info
expand_more
Publication Year
2018
Language
English
Copyright
© 2018 J.C.J. Gude, K. Joris, K. Huysman, L.C. Rietveld, D. van Halem
Research Group
Sanitary Engineering
Volume number
1
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract


Current groundwater treatment facilities, mostly relying on aeration-filtration configurations, aim at the removal of iron (Fe), ammonia (NH
4

+
) and manganese (Mn). However, recently water companies expressed the ambition to also reduce arsenic (As) concentrations in these rapid sand filters. The aim of this study was to investigate the effect of the Fe oxidation state entering a biological filter bed on As removal. By varying supernatant water level, either Fe(II) or Fe(III) in the form of hydrous ferric oxides (HFO) could be stimulated to enter the filter bed at alkaline groundwater pH (7.6). The experimental pilot column filters showed that once the As(III) oxidation stabilised in the top layer of the filter sand, As removal reached its maximum (±75% at 120 cm supernatant level and 1.5 m/h filtration velocity). The increase in supernatant level from 5 to 120 cm resulted in additional HFO production prior to rapid filtration (1.5, 5 and 10 m/h), i.e. homogeneous Fe(II) oxidation and flocculation, and subsequently, HFO ending up deeper into the filter bed (120 cm filter depth). At a low supernatant water level of 5 cm, Fe(II) oxidised heterogeneously and was removed within the top 20 cm of the filter bed. Consequently, filters with high supernatant levels removed As to lower levels (by 20%) than in filters with low supernatant water levels. The benefits of Fe(II) oxidation prior to filtration for As removal was confirmed by comparing Fe(III) to Fe(II) additions in the supernatant water or in the filter bed. Overall it is concluded that in biological groundwater filters, the combination of a higher supernatant level and/or Fe(III) addition with biological As(III) oxidation in the top of the filter bed promotes As removal.