Fv
F.J. van Buren
info
Please Note
<p>This page displays the records of the person named above and is not linked to a unique person identifier. This record may need to be merged to a profile.</p>
2 records found
1
Currently, the entire aviation sector accounts for 2.5% of global emissions. To commit to the Paris Agreement by 2050, new emerging technology is necessary. Electric aircraft emerged as one of the promising solutions to decarbonize the aviation sector. However, the introduction of electric aviation (EA) causes a shift from kerosene to electricity. With the minimized turnaround times of aircraft, high charging powers are encountered with the adoption of electric aircraft. This can in turn lead to grid instability and costly grid infrastructure upgrades for the grid operator. A battery energy storage system (BESS) can potentially be a promising solution capable of addressing the high power rates associated with electric aircraft charging. Moreover, it provides opportunities for the battery owner to reduce costs and increase the utilization of renewable energy. This thesis aims to gain insight into the contribution of the deployment of a BESS compared to the business-as-usual situation to enable electric aviation while facilitating the interests of both the grid operator and the airport. In particular, this is done for the case study of Bonaire International Airport (BIA) and the grid operator Water- en Energiebedrijf Bonaire (WEB). For the grid operator, the impact on the grid is analyzed focusing on the voltage fluctuations, the load on the distribution cables, and the airport’s transformer (over)loading. From the airport’s perspective, the airport system’s LCOE, and the CO2 emissions from grid electricity are investigated.
Lastly, as electric aviation is currently not commercially used, and faces a lot of uncertainty, the sensitivity of the control strategies to various future scenarios for 2030 is analyzed. This is investigated by a mathematical optimization model for the three battery control strategies, Self-Consumption, Peak-Shaving, and Cost-Optimal. The results showed that in the absence of a BESS, the business-as-usual situation, independent of the adoption level of electric aviation at BIA, the transformer required a capacity upgrade. With the deployment of a BESS, it was found that a Self-consumption-controlled BESS could not effectively reduce the peak loads and defer a transformer capacity upgrade. While voltage fluctuations remained within the acceptable operational range for each control strategy and adoption level of EA. On the other hand, future scenarios with high demand growth could lead voltage fluctuations to reach the allowable threshold. The Self-Consumption strategy is susceptible to an increased electricity demand and adoption level of EA, which substantially influences the load on the distribution cables. Conversely, the Peak-Shaving and Cost-Optimal battery significantly reduces the peak loads in both electricity demand and injection even in scenarios with increased electricity demand and higher adoption levels of EA. Economically, it was shown that a BESS substantially reduced the LCOE depending on the control strategy. Furthermore, it is feasible to reduce CO2 emissions originating from grid electricity production, albeit the reduction is strongly affected by increased electricity demand over time. The research concluded that a BESS is able to defer grid infrastructure upgrades and reduce costs for the airport, although, the extent of these results is highly dependent on the control strategy. Regardless of the control strategies, a battery is able to achieve a reduction in CO2 emissions from the grid given the on-site PV system. ...
Lastly, as electric aviation is currently not commercially used, and faces a lot of uncertainty, the sensitivity of the control strategies to various future scenarios for 2030 is analyzed. This is investigated by a mathematical optimization model for the three battery control strategies, Self-Consumption, Peak-Shaving, and Cost-Optimal. The results showed that in the absence of a BESS, the business-as-usual situation, independent of the adoption level of electric aviation at BIA, the transformer required a capacity upgrade. With the deployment of a BESS, it was found that a Self-consumption-controlled BESS could not effectively reduce the peak loads and defer a transformer capacity upgrade. While voltage fluctuations remained within the acceptable operational range for each control strategy and adoption level of EA. On the other hand, future scenarios with high demand growth could lead voltage fluctuations to reach the allowable threshold. The Self-Consumption strategy is susceptible to an increased electricity demand and adoption level of EA, which substantially influences the load on the distribution cables. Conversely, the Peak-Shaving and Cost-Optimal battery significantly reduces the peak loads in both electricity demand and injection even in scenarios with increased electricity demand and higher adoption levels of EA. Economically, it was shown that a BESS substantially reduced the LCOE depending on the control strategy. Furthermore, it is feasible to reduce CO2 emissions originating from grid electricity production, albeit the reduction is strongly affected by increased electricity demand over time. The research concluded that a BESS is able to defer grid infrastructure upgrades and reduce costs for the airport, although, the extent of these results is highly dependent on the control strategy. Regardless of the control strategies, a battery is able to achieve a reduction in CO2 emissions from the grid given the on-site PV system. ...
Currently, the entire aviation sector accounts for 2.5% of global emissions. To commit to the Paris Agreement by 2050, new emerging technology is necessary. Electric aircraft emerged as one of the promising solutions to decarbonize the aviation sector. However, the introduction of electric aviation (EA) causes a shift from kerosene to electricity. With the minimized turnaround times of aircraft, high charging powers are encountered with the adoption of electric aircraft. This can in turn lead to grid instability and costly grid infrastructure upgrades for the grid operator. A battery energy storage system (BESS) can potentially be a promising solution capable of addressing the high power rates associated with electric aircraft charging. Moreover, it provides opportunities for the battery owner to reduce costs and increase the utilization of renewable energy. This thesis aims to gain insight into the contribution of the deployment of a BESS compared to the business-as-usual situation to enable electric aviation while facilitating the interests of both the grid operator and the airport. In particular, this is done for the case study of Bonaire International Airport (BIA) and the grid operator Water- en Energiebedrijf Bonaire (WEB). For the grid operator, the impact on the grid is analyzed focusing on the voltage fluctuations, the load on the distribution cables, and the airport’s transformer (over)loading. From the airport’s perspective, the airport system’s LCOE, and the CO2 emissions from grid electricity are investigated.
Lastly, as electric aviation is currently not commercially used, and faces a lot of uncertainty, the sensitivity of the control strategies to various future scenarios for 2030 is analyzed. This is investigated by a mathematical optimization model for the three battery control strategies, Self-Consumption, Peak-Shaving, and Cost-Optimal. The results showed that in the absence of a BESS, the business-as-usual situation, independent of the adoption level of electric aviation at BIA, the transformer required a capacity upgrade. With the deployment of a BESS, it was found that a Self-consumption-controlled BESS could not effectively reduce the peak loads and defer a transformer capacity upgrade. While voltage fluctuations remained within the acceptable operational range for each control strategy and adoption level of EA. On the other hand, future scenarios with high demand growth could lead voltage fluctuations to reach the allowable threshold. The Self-Consumption strategy is susceptible to an increased electricity demand and adoption level of EA, which substantially influences the load on the distribution cables. Conversely, the Peak-Shaving and Cost-Optimal battery significantly reduces the peak loads in both electricity demand and injection even in scenarios with increased electricity demand and higher adoption levels of EA. Economically, it was shown that a BESS substantially reduced the LCOE depending on the control strategy. Furthermore, it is feasible to reduce CO2 emissions originating from grid electricity production, albeit the reduction is strongly affected by increased electricity demand over time. The research concluded that a BESS is able to defer grid infrastructure upgrades and reduce costs for the airport, although, the extent of these results is highly dependent on the control strategy. Regardless of the control strategies, a battery is able to achieve a reduction in CO2 emissions from the grid given the on-site PV system.
Lastly, as electric aviation is currently not commercially used, and faces a lot of uncertainty, the sensitivity of the control strategies to various future scenarios for 2030 is analyzed. This is investigated by a mathematical optimization model for the three battery control strategies, Self-Consumption, Peak-Shaving, and Cost-Optimal. The results showed that in the absence of a BESS, the business-as-usual situation, independent of the adoption level of electric aviation at BIA, the transformer required a capacity upgrade. With the deployment of a BESS, it was found that a Self-consumption-controlled BESS could not effectively reduce the peak loads and defer a transformer capacity upgrade. While voltage fluctuations remained within the acceptable operational range for each control strategy and adoption level of EA. On the other hand, future scenarios with high demand growth could lead voltage fluctuations to reach the allowable threshold. The Self-Consumption strategy is susceptible to an increased electricity demand and adoption level of EA, which substantially influences the load on the distribution cables. Conversely, the Peak-Shaving and Cost-Optimal battery significantly reduces the peak loads in both electricity demand and injection even in scenarios with increased electricity demand and higher adoption levels of EA. Economically, it was shown that a BESS substantially reduced the LCOE depending on the control strategy. Furthermore, it is feasible to reduce CO2 emissions originating from grid electricity production, albeit the reduction is strongly affected by increased electricity demand over time. The research concluded that a BESS is able to defer grid infrastructure upgrades and reduce costs for the airport, although, the extent of these results is highly dependent on the control strategy. Regardless of the control strategies, a battery is able to achieve a reduction in CO2 emissions from the grid given the on-site PV system.
Bachelor thesis
(2021)
-
F.J.M. van Eijnatten, F. Uijtewaal, F.J. van Buren, K.W. Verloop, B.J. Boersma, R. Delfos
To improve the efficiency of domestic heat energy use, a heat battery was added to a boiler. This heat battery contains a phase change material (PCM) characterized by low thermal conductivity and high specific heat, enabling efficient storage of residual heat energy. Paraffin wax was selected due to its high latent heat storage capacity; however, its low thermal conductivity posed challenges regarding storage time. To address this, a finned tube was introduced, and the feasibility of the heat battery for domestic applications was investigated. The effectiveness of the finned tube was evaluated using both a numerical model and an experiment. In the experiment, a temperature- and flow-adjustable water source was connected to a plain tube and a finned tube, with temperature and heat flux measurements recorded to assess the impact of the fin structure. These conditions were replicated in the numerical model for comparison. The results indicated that heat extraction from the PCM using the finned tube required approximately 60 minutes, compared to nearly five hours with the plain tube. These findings suggest that while the method shows promise, further development is needed before it is suitable for domestic implementation.
...
To improve the efficiency of domestic heat energy use, a heat battery was added to a boiler. This heat battery contains a phase change material (PCM) characterized by low thermal conductivity and high specific heat, enabling efficient storage of residual heat energy. Paraffin wax was selected due to its high latent heat storage capacity; however, its low thermal conductivity posed challenges regarding storage time. To address this, a finned tube was introduced, and the feasibility of the heat battery for domestic applications was investigated. The effectiveness of the finned tube was evaluated using both a numerical model and an experiment. In the experiment, a temperature- and flow-adjustable water source was connected to a plain tube and a finned tube, with temperature and heat flux measurements recorded to assess the impact of the fin structure. These conditions were replicated in the numerical model for comparison. The results indicated that heat extraction from the PCM using the finned tube required approximately 60 minutes, compared to nearly five hours with the plain tube. These findings suggest that while the method shows promise, further development is needed before it is suitable for domestic implementation.