W.G.J. van der Meer
Please Note
23 records found
1
Nature-inspired water purification
Integrating riverbank filtration and biofilm-regulating nanofiltration
Nanofiltration (NF) is an effective method for removing various emerging pollutants in drinking water. However, its conventional application, primarily adapted from desalination practices, faces challenges such as stringent pretreatment requirements, high energy consumption, and severe membrane fouling. To address these issues, we modified the NF process by transitioning from the traditional spiral-wound configuration to a submerged flat-sheet configuration and incorporating riverbank filtration (RBF) as a pretreatment. Experimental results demonstrated that the RBF-NF system could selectively remove natural organic matter (60.6 %) and various trace organic compounds (30.7 %–68.0 %), without the losses of beneficial ions. Additionally, the RBF-NF system reduced the risk of microbial regrowth in treated water by effectively lowering assimilable organic carbon and phosphorus levels, with removal of 52.1 % and 35.0 %, respectively. More importantly, a membrane biofilm naturally developed on the NF membrane surface over a 6-month filtration period, which facilitated the self-cleaning of the NF by biodegrading foulants and loosening the fouling cake structure. This resulted in stabilized filtration without an increase in transmembrane pressure, highlighting the potential for cleaning-free and low-maintenance operation. Additionally, the RBF-NF process reduced energy consumption by 94.6 % and carbon emissions by 87.4 % compared to traditional NF processes, primarily through the reduction of driving pressure and the elimination of crossflow. These findings demonstrate that RBF-NF is an efficient, chemical-free, and nature-based water treatment technology with significant operational and environmental benefits.
The excessive use and accumulation of water-soluble polymers (WSPs, known as “liquid plastics”) in the environment can pose potential risks to both ecosystems and human health, but the environmental fate of WSPs remains unclear. Here, the adsorption behavior of WSPs with different molecular weight on kaolinite (Kaol) and montmorillonite (Mt) were examined. The results showed that the adsorption of PEG and PVP on minerals were controlled by hydrogen bond and van der Waals force. The Fourier transform infrared (FTIR) spectra and two-dimensional correlation spectroscopy (2D-COS) analysis revealed that there were interactions between the Al-O and Si-O groups of the minerals and the polar O- or N-containing functional groups as well as the alkyl groups of PEG and PVP. The adsorption characteristics of WSPs were closely related to their molecular weight and the pore size of minerals. Due to the relatively large mesopore size of Kaol, both PEG and PVP were absorbed into inner spaces, for which the adsorption capacity increased with molecular weight of the polymers. For Mt, all types of PEG could enter its micropores, while PVP with larger molecular weights appeared to be confined externally, leading to a decrease in the adsorption capacity of PVP with increasing molecular weight. The findings of this study provide a theoretical basis for scientific evaluation of environmental processes of WSPs.
Pipe materials appear to play an important role in the development of biofilms in drinking water distribution systems. However, there is controversy as to whether pipe materials shape the composition and diversity of bacterial communities in biofilms. To investigate the long-term effects of pipe materials on biofilms, triplicate samples of mature biofilms on unplasticized polyvinyl chloride (PVC-U), grey cast iron and asbestos cement (pipe age > 40 years) were obtained from three areas of an unchlorinated drinking water distribution system in the Netherlands. Illumina sequencing was performed and 773 OTUs (730 OTUs-814 OTUs) were detected within the biofilms on the three pipe materials, all of which were dominated by Proteobacteria (36.2%-46.1%). Both the alpha and beta diversity results showed that the bacterial communities of the biofilms formed on different pipe materials were highly similar. The neutral community model revealed that the assembly of the biofilm communities was governed by environmental selection rather than neutral processes. Among the 142 shared OTUs between the water and biofilm samples, there were 25 enriched OTUs (e.g., OTU7, assigned as Nitrospira spp.), which accounted for 62.6% of the total sequences, while 16 OTUs were disadvantaged (e.g., OTU14 and OTU40, assigned as Hyphomicrobiaceae), accounting for 2.2% of the sequences. Based on the findings, we propose and discuss a harmonisation process by which biofilms with significant differences due to the pipe material harmonize over time resulting in biofilms with similar bacterial communities. Our findings provide valuable insights into long-term biofilm development, bridging an essential gap in our current understanding of the influence of pipe materials on biofilm communities. These findings also highlight the importance of long-term studies and point to a potentially masked harmonizing process during biofilm development over years/decades.
Assessing the transition effects in a drinking water distribution system caused by changing supply water quality
An indirect approach by characterizing suspended solids
Worldwide, it is common that the drinking water distribution systems (DWDSs) may be subjected to changes of supply water quality due to the needs of upgrading the treatment processes or switching the source water. However, the potential impacts of quality changed supply water on the stabilized ecological niches within DWDSs and the associated water quality deterioration risks were poorly documented. In the present study, such transition effects caused by changing the supply water quality that resulted from destabilization of biofilm and loose deposits in DWDS were investigated by analyzing the physiochemical and microbiological characteristics of suspended particles before (T0), during (T3-weeks) and after upgrading the treatments (T6-months) in an unchlorinated DWDS in the Netherlands. Our results demonstrated that after 6 months’ time the upgraded treatments significantly improved the water quality. Remarkably, water quality deterioration was observed at the initial stage when the quality-improved treated water distributed into the network at T3-weeks, observed as a spike of total suspended solids (TSS, 50–260%), active biomass (ATP, 95–230%) and inorganic elements (e.g. Mn, 130–250%). Furthermore, pyrosequencing results revealed sharp differences in microbial community composition and structure for the bacteria associated with suspended particles between T0 and T3-weeks, which re-stabilized after 6 months at T6-months. The successful capture of transition effects was especially confirmed by the domination of Nitrospira spp. and Polaromonas spp. in the distribution system at T3-weeks, which were detected at rather low relative abundance at treatment plant. Though the transitional effects were captured, this study shows that the introduction of softening and additional filtration did not have an effect on the water quality for the consumer which improved considerably after 6-months’ period. The methodology of monitoring suspended particles with MuPFiSs and additional analysis is capable of detecting transitional effects by monitoring the dynamics of suspended particles and its physiochemical and microbiological composition.
In the present study, triplicate rings of 360° pipe surfaces of an operational drinking water distribution pipe were swabbed. Each ring was equally divided into 16 parts for swabbing. The collected swabs were grouped into 3 sections and compared with the biofilm samples sampled by sonication of specimens from the same pipe. The results showed that the biofilm is unevenly distributed over the 16 parts and the 3 sections of the pipe surface. Both the active biomass and the number of observed OTUs increased as the measurements proceeded from the top to the bottom of the pipe. The bacterial community was dominated in all sections by Proteobacteria. At the genus level, Nitrospira spp., Terrimonas spp., and Hyphomicrobium spp. were dominant in all sections. Gaiella spp. and Vicinamibacter spp. dominated in S-I, Blastopirellula spp. and Pirellula spp. dominated in S-II, while Holophaga spp. and Phaeodactylibacter spp. dominated in S-III. When swabbing and pipe specimen sonication were compared, the results showed that the sampling strategy significantly influences the obtained biofilm bacterial community. A consistent multisectional swabbing strategy is proposed for future biofilm sampling; it involves collecting swabs from all sections and comparing the swabs from the same position/section across locations.
Coagulation is the best available method for removing intracellular organic matter (IOM), which is released from algae cells and is an important precursor to disinfection by-products in drinking water treatment. To gain insight into the best strategy to optimize IOM removal, the coagulation performance of two Al salts, i.e., aluminum chloride (AlCl3) and polyaluminum chloride (PACl, containing 81.2% Al13), was investigated to illuminate the effect of Al species distribution on IOM removal. PACl showed better removal efficiency than AlCl3 with regard to the removal of turbidity and dissolved organic carbon (DOC), owing to the higher charge neutralization effect and greater stability of pre-formed Al13 species. High pressure size exclusion chromatography analysis indicated that the superiority of PACl in DOC removal could be ascribed to the higher binding affinity between Al13 polymer and the low and medium molecular weight (MW) fractions of IOM. The results of differential log-transformed absorbance at 254 and 350 nm indicated more significant formation of complexes between AlCl3 and IOM, which benefits the removal of tryptophan-like proteins thereafter. Additionally, PACl showed more significant superiority compared to AlCl3 in the removal of < 5 kDa and hydrophilic fractions, which are widely viewed as the most difficult to remove by coagulation. This study provides insight into the interactions between Al species and IOM, and advances the optimization of coagulation for the removal of IOM in eutrophic water.
Feed spacer orientation affects the velocity pattern and pressure drop of spacer-filled channels such as those encountered in Spiral-wound Membrane (SWM) modules of Reverse Osmosis (RO). However, there are only limited numbers of experimental studies on this topic. This study sets out to reveal more detailed information on the pressure drop and velocity patterns of spacer-filled channels. Particle Image Velocimetry (PIV) is used to provide high-resolution velocity maps for three commercial feed spacers of different thicknesses at a flow attack angle of 45° and 90°. The pressure drop is measured for the applied operational conditions (Re < 250). Results showed higher pressure losses, a better mixing of flow, a lower variation of temporal velocity, and a smaller variation of velocity over the channel height in the orientation with a flow attack angle of 45° as compared to 90°. The results presented here can be used to validate numerical studies, determine the fouling-sensitive regions in a spacer-filled channel and consequently, design the optimal spacer with respect to its orientation and thickness.
The results of this sampling campaign on pilot scale processes aim to evaluate the occurrence and behavior of trace organic micro-pollutants and metal elements during anion exchange treatment of surface water and the subsequent treatment of generated spent brine with two types of electrodialysis membrane pairs. This knowledge is relevant to assess the quality and reusability of secondary products created during brine treatment; specifically the excess of sodium chloride to be recycled onsite and the natural organic matter, mostly consisting of humic substances, which find multiple applications in the agricultural industry. This study highlights that (1) the attachment mechanism of organic micro-pollutants to anion exchange resin occurs through electrostatic interaction and the subsequent transfer through ion exchange membranes is restricted by size exclusion; and (2) the complexation of trace metals compounds with the natural organic matter partly explains their removal by anion exchange. Complexes remain stable during treatment of the brine with electrodialysis.
The integration of adsorbents with ultrafiltration (UF) membranes is a promising method for alleviating membrane fouling and reducing land use. However, adsorbents typically are only injected into the membrane tank once, resulting in a single dynamic protection layer and low removal efficiency over long-term operation. In addition, the granular adsorbents used can cause membrane surface damage. To overcome these disadvantages, we injected inexpensive and loose aluminum (Al)-based flocs directly into a membrane tank with bottom aeration in the presence of humic acid (HA) or raw water taken from the Miyun Reservoir (Beijing, China). Results showed that the flocs were well suspended in the membrane tank, and multiple dynamic floc protection layers were formed (sandwich-like) on the membrane surface with multiple batch injections. Higher frequency floc injections resulted in better floc utilization efficiency and less severe membrane fouling. With continuous injection, acid solutions demonstrated better performance in removing HA molecules, especially those with small molecular weight, and in alleviating membrane fouling compared with the use of high aeration rate or polyacrylamide injection. This was attributed to the small particle size, large specific surface area, and high zeta potential of the flocs. Additionally, excellent UF membrane performance was exhibited by reservoir water with continuous injection and acid solution. Based on the outstanding UF membrane performance, this innovative integrated filtration with loose Al-based flocs has great application potential for water treatment.
The general consensus is that the abundance of tap water bacteria is greatly influenced by water purification and distribution. Those bacteria that are released from biofilm in the distribution system are especially considered as the major potential risk for drinking water bio-safety. For the first time, this full-scale study has captured and identified the proportional contribution of the source water, treated water, and distribution system in shaping the tap water bacterial community based on their microbial community fingerprints using the Bayesian “SourceTracker” method. The bacterial community profiles and diversity analyses illustrated that the water purification process shaped the community of planktonic and suspended particle-associated bacteria in treated water. The bacterial communities associated with suspended particles, loose deposits, and biofilm were similar to each other, while the community of tap water planktonic bacteria varied across different locations in distribution system. The microbial source tracking results showed that there was not a detectable contribution of source water to bacterial community in the tap water and distribution system. The planktonic bacteria in the treated water was the major contributor to planktonic bacteria in the tap water (17.7–54.1%). The particle-associated bacterial community in the treated water seeded the bacterial community associated with loose deposits (24.9–32.7%) and biofilm (37.8–43.8%) in the distribution system. In return, the loose deposits and biofilm showed a significant influence on tap water planktonic and particle-associated bacteria, which were location dependent and influenced by hydraulic changes. This was revealed by the increased contribution of loose deposits to tap water planktonic bacteria (from 2.5% to 38.0%) and an increased contribution of biofilm to tap water particle-associated bacteria (from 5.9% to 19.7%) caused by possible hydraulic disturbance from proximal to distal regions. Therefore, our findings indicate that the tap water bacteria could possibly be managed by selecting and operating the purification process properly and cleaning the distribution system effectively.
Making improvements to feed spacers of spiral-wound membrane (SWM) modules of reverse osmosis (RO) is a necessary step towards a wider application of these modules. This study sets out to evaluate the performance of six commercial feed spacers by comparing their actual velocity profiles and their pressure drop. Velocity profiles are obtained from Particle Image Velocimetry (PIV). Comparing images from PIV with corresponding friction losses revealed that the transition from steady to unsteady flow occurs at the moment when the incline of the friction factor changes from steep to slight. From the two types of spacers used, zigzag spacers showed a better distribution of flow than the cavity spacers did, but at the cost of higher pressure drop. The flow was in a straight line from inlet to outlet with zigzag spacers only at low Reynolds numbers and with cavity spacers for the entire studied range of Reynolds numbers. Additionally, results showed that hydraulic conditions in channels with cavity spacers are mainly affected by geometric characteristics of transverse filaments. The results from this study can be used to understand the effects of spacer geometry on the hydraulic conditions inside the feed channel and as a validation tool for computational modeling.
Spiral-wound membrane (SWM) modules are the most common membrane configuration utilized in reverse osmosis (RO) and nanofiltration. The enhancement of SWM module design, particularly in the geometric design of the feed spacer, can play a crucial role in the cost and the potential for wider application of these modules. The feed spacer influences the flux, pressure losses and fouling in the membrane process and consequently the product water unit cost. Despite the shift in the application of SWM modules of RO toward low salinity sources and the resulting higher sensitivity performance using these waters, the configuration and orientation of feed spacers have not significantly changed since the original design. A wider use of SWM modules, therefore, requires the adaptation of geometric parameters of the feed spacer to the water source. Improving the feed spacer's design according to the feed water type requires the knowledge of previous studies conducted in spacer-filled channels as well as further needed investigations in future. This paper reviews the role of the feed spacer in SWM modules and provides an overview of studies conducted in narrow spacer-filled channels to determine the effect of different geometric characteristics of the feed spacer on hydraulic conditions.
Ensuring the biological stability of drinking water is essential for modern drinking water supply. To understand and manage the biological stability, it is critical that the bacterial growth in drinking water can be measured. Nowadays, advance treatment technologies, such as reverse osmosis (RO), are increasingly applied in drinking water purification where the produced water is characterized by low levels of nutrients and cell counts. The challenge is, therefore, how to measure the low bacterial growth potential (BGP) of such ultra-pure water using the available methods which were originally developed for conventionally treated drinking water. In this study, we proposed a protocol to assess BGP of ultra-pure drinking water produced by RO and post-treatment (including remineralization). Natural bacterial consortium from conventional drinking water was added to all water samples during this study to ensure the presence of a wide range of bacterial strains. The method development included developing an ultra-pure blank with high reproducibility to lower the detection limit of the BGP method (50 ± 20 × 103 intact cells/mL) compared with conventional blanks such as bottled spring water, deep groundwater treated by aeration and slow sand filtrate of surface water supply. The ultra-low blank consists of RO permeate after adjusting its pH and essential mineral content under controlled laboratory conditions to ensure carbon limitation. Regarding the test protocol, inoculum concentrations of >10 × 103 intact cells/mL may have a significant contribution to the measured low levels of BGP. Pasteurization of water samples before measuring BGP is necessary to ensure reliable bacterial growth curves. The optimized method was used to assess BGP of ultra-pure drinking water produced by RO membranes and post-treatment (including remineralization), where the BGP has decreased more than 6-fold to a level of 90 ± 20 × 103 intact cells/mL compared with conventionally treated water (630 ± 70 × 103 intact cells/mL).
Driven by the development of water purification technologies and water quality regulations, the use of better source water and/or upgraded water treatment processes to improve drinking water quality have become common practices worldwide. However, even though these elements lead to improved water quality, the water quality may be impacted during its distribution through piped networks due to the processes such as pipe material release, biofilm formation and detachment, accumulation and resuspension of loose deposits. Irregular changes in supply-water quality may cause physiochemical and microbiological de-stabilization of pipe material, biofilms and loose deposits in the distribution system that have been established over decades and may harbor components that cause health or esthetical issues (brown water). Even though it is clearly relevant to customers’ health (e.g., recent Flint water crisis), until now, switching of supply-water quality is done without any systematic evaluation. This article reviews the contaminants that develop in the water distribution system and their characteristics, as well as the possible transition effects during the switching of treated water quality by destabilization and the release of pipe material and contaminants into the water and the subsequent risks. At the end of this article, a framework is proposed for the evaluation of potential transition effects.
PURO
A unique RO-design for brackish groundwater treatment
Depletion of fresh groundwater sources as the result of overdraft, salinization and pollution becomes a major problem in parts of the world. Desalination of brackish groundwater by membrane technology, e.g. reverse osmosis (RO), seems to be a promising solution to water scarcity problems. However, energy consumption and concentrate disposal are considered as the main reasons for avoiding RO application. In order to overcome these drawbacks, the PURO concept, which consists of vertically-configured RO unit in an especially drilled well is designed, installed and is going to be tested. The installation operates without any chemical pretreatment and therefore, the concentrate can be injected into a deeper confined aquifer that contains water of similar concentration. To avoid chemical pretreatment, the system operates at lower recovery (50%) than conventional brackish groundwater reverse osmosis (BWRO). Higher energy consumption, as the results of lowering the recovery, is avoided by using natural hydrostatic pressure at the depth that RO is installed and by extracting the permeate water only. PURO consumes about 39% less energy when compared to a conventional BWRO installation of the same capacity. This article describes the PURO concept and discusses its advantages and disadvantages. It also provides a rough calculation of water cost for PURO and conventional BWRO with emphasizing on the energy costs.
Biofilm formation, loose deposit accumulation and water quality deterioration in drinking water distribution systems have been widely reported. However, the accumulation and distribution of harbored elements and microbes in the different niches (loose deposits, PVC-U biofilm, and HDPE biofilm) and their corresponding potential contribution to water quality deterioration remain unknown. This precludes an in-depth understanding of water quality deterioration and the development of proactive management strategies. The present study quantitatively evaluated the distribution of elements, ATP, Aeromonas spp., and bacterial communities in distribution pipes (PVC-U, D = 110 mm, loose deposit and biofilm niches) and household connection pipes (HDPE, D = 32 mm, HDPE biofilm niches) at ten locations in an unchlorinated distribution system. The results show that loose deposits in PVC-U pipes, acting as sinks, constitute a hotspot (highest total amount per meter pipe) for elements, ATP, and target bacteria groups (e.g., Aeromonas spp., Mycobacterium spp., and Legionella spp.). When drinking water distribution system niches with harbored elements and microbes become sources in the event of disturbances, the highest quality deterioration potential (QDP) is that of HDPE biofilm; this can be attributed to its high surface-to-volume ratio. 16s rRNA analysis demonstrates that, at the genus level, the bacterial communities in the water, loose deposits, PVC-U biofilm, and HDPE biofilm were dominated, respectively, by Polaromonas spp. (2–23%), Nitrosipra spp. (1–47%), Flavobacterium spp. (1–36%), and Flavobacterium spp. (5–67%). The combined results of elemental composition and bacterial community analyses indicate that different dominant bio-chemical processes might occur within the different niches—for example, iron-arsenic oxidizing in loose deposits, bio-calumniation in PVC-U biofilm, and methane oxidizing in HDPE biofilm. The release of 20% loose deposits, 20% PVC-U biofilm and 10% HDPE biofilm will cause significant changes of water bacterial community.
Visualization of hydraulic conditions inside the feed channel of Reverse Osmosis
A practical comparison of velocity between empty and spacer-filled channel