Objective. In brachytherapy for gynecological cancers using intracavitary applicators, implant reconstruction is commonly performed using applicator libraries. These libraries contain applicator geometry models as well as dwell position (DP) models defined in respect to the applicator geometry. In this study, we investigate whether an afterloader integrated electromagnetic tracking (EMT) system can be utilized for DP model definition and quality assurance in such applicators. Approach. DPs in four sets of two configurations of the Elekta Venezia Advanced Gynaecological Applicator (22 mm ovoids/40 mm intrauterine (IU) and 26 mm ovoids/70 mm IU) were measured using an afterloader integrated EMT system. Measurements were evaluated for reproducibility and compared against manufacturer-specified (MS) DPs and a computed tomography (CT)-corrected DP model. Main Results. Excellent EMT measurement reproducibility was observed, with values of ⩽0.2 mm for both configurations. The overall reproducibility, including applicator geometry reproducibility, was ⩽0.4 mm for both configurations. Significant discrepancies from the manufacturer’s DP model were observed, with a mean ± sd deviation of 1.13 ± 0.66 mm (22/40) and 1.37 ± 0.63 (26/70), particularly in the IU channel, where MS DPs were not experimentally defined. Discrepancies were reduced to 0.89 ± 0.41 mm (22/40) and 0.81 ± 0.33 mm (26/70) when the CT-corrected DP model was used as baseline, highlighting the need for experimentally defined DP models. The overall uncertainty of single measurements was below the clinically acceptable 2 mm limit. Significance. This study confirms that afterloader integrated EMT can accurately reconstruct source paths in gynecological brachytherapy applicators and supports its incorporation into clinical workflows for improved quality assurance and treatment precision. The importance of EMT for quality assurance was highlighted by measured deviations from manufacturer’s DP model in a clinical relevant part of the IU channel.
Objective. A dynamic model is developed to predict the impact of radiotherapy on circulating lymphocyte counts in women with locally advanced cervical cancer (LACC). This study aims to compare the effects of photon and proton therapy, as well as the influence of bone marrow sparing (BMS) techniques, on relative lymphocyte preservation over time. Approach. A dynamic lymphocyte flow model was developed to simulate the migration of lymphocytes based on seven compartments. Biological cell death and lymphocyte production were integrated across compartments. The lymphocyte flow model was applied to 19 LACC patients. Volumetric modulated arc therapy (VMAT) and intensity modulated proton therapy (IMPT) treatment plans were created for each patient without BMS and with BMS. The model calculated radiation dose to lymphocytes to estimate radiation-induced cell death over time. The output of the model was the relative lymphocyte count relative to baseline (RLC) over time and the RLC nadir in the blood and total body. Main results. According to the model, IMPT resulted in lower doses to lymphocyte and higher RLC nadirs compared to VMAT for all 19 patients. The total RLC nadir (mean ± SD) was 48.4% ± 4.0% for VMAT and 62.5% ± 5.1% for IMPT. In the blood compartment, the RLC nadir was 32.7% ± 3.5% for VMAT and 47.7% ± 5.9% for IMPT. The RLC nadir in the blood compartment improved with 3Gy BMS from 32.7% ± 3.5% to 33.0% ± 3.5% , while it decreased for IMPT from 47.7% ± 5.9% to 46.6% ± 6.0%. Total RLC nadir decreased with BMS for VMAT from 48.4% ± 4.0% to 48.2% ± 3.9% and for IMPT from 62.5% ± 5.1% to 60.9% ± 5.3%. Significance. By incorporating a dynamic flow model, we predicted the RLC over time. The model predicted a substantial sparing effect IMPT has on the lymphocytes compared to VMAT. This sparing was both present in the blood and the total body. Sparing the bone marrow showed only a minimal effect on the RLC.
The interest in hybrid nanoparticles for various applications in biomedicine is growing inevitably, stimulating research towards not only more effective, but also more accessible systems. This resulted in the emergence of advanced synthetic protocols with optimized conditions for the production of nanoparticles with high yields and desired morphologies, which ultimately determine their physicochemical and biomedical properties. While these challenges were sufficient for scientists a few decades ago, the sustainability of the synthetic methods is now an important aspect. From this perspective, nanoparticle production methods based on physical principles, such as spark discharge phenomena, could provide an interesting alternative to labor-intensive and environmentally harmful chemical synthesis. The benefits of clean and sustainable physical production routes for various nanomaterials are already recognized in the fields of catalysis and electronics. Biomedicine on the other hand has been reluctant to embrace the new methodologies, as they do not inherently provide nanoparticles dispersed in aqueous media, which is essential for their safe administration and reliable physiological performance. In this work, we investigated the potential of spark discharge as an alternative method to produce hybrid palladium/iron oxide nanoparticles intended for cancer thermo-brachytherapy by leveraging the magnetothermal properties of iron and the favorable radioactive features of the palladium radioisotope. Focusing on the aqueous harvesting of the nanoparticles produced in VSParticle’s spark discharge generator, we determined the optimal settings compatible with the connected bubbling column and identified the pitfalls and possible solutions to the intrinsic challenges, such as low yields and aggregation.
Objective: To investigate the potential of hybrid Pd/Fe-oxide magnetic nanoparticles designed for thermo-brachytherapy of breast cancer, considering their specific loss power (SLP) and clinical constraints in the applied magnetic field. Methods: Hybrid nanoparticles consisting of palladium-core and iron oxide shell of increasing thickness, were suspended in water and their SLPs were measured at varying magnetic fields (12–26 mT peak) and frequencies (50–730 kHz) with a commercial alternating magnetic field generator (magneTherm™ Digital, nanoTherics Ltd.). Results: Validation of the heating device used in this study with commercial HyperMag-C nanoparticles showed a small deviation (±4%) over a period of 1 year, confirming the reliability of the method. The integration of dual thermometers, one in the center and one at the bottom of the sample vial, allowed monitoring of homogeneity of the sample suspensions. SLPs measurements on a series of nanoparticles of increasing sizes showed the highest heating for the diameter of 21 nm (SLP = 225 W/g) at the applied frequencies of 346 and 730 kHz. No heating was observed for the nanoparticles with the size <14 nm, confirming the importance of the size-parameter. The heating ability of the best performing Pd/Fe-oxide-21 was calculated to be sufficient to ablate tumors with a radius ±4 and 12 mm using 10 and 1 mg/mL nanoparticle concentration, respectively. Conclusions: Nanoparticles consisting of non-magnetic palladium-core and magnetic iron oxide shell are suitable for magnetic hyperthermia/thermal ablation under clinically safe conditions of 346 kHz and 19.1 mT, with minimal eddy current effects in combination with maximum SLP.