Shear wave tracking

Open chest versus closed chest

This paper describes an in-vivo pilot study in which the systolic myocardial stiffness of four pigs was measured with various acoustic techniques. We compare the propagation velocity of shear waves in open chest and closed chest experiments, in which the open-chest shear wave was ...
Purpose: To study the feasibility of high-frame-rate (HFR) contrast material-enhanced (CE) ultrasound particle image velocimetry (PIV), or echo PIV, in the abdominal aorta. Materials and Methods: Fifteen healthy participants (six men; median age, 23 years [age range, 18-34 years] ...
Treatment of abdominal aortic (AA) aneurysms and stenotic lesions may be improved by analyzing their associated blood flow patterns. Angle-independent blood flow patterns in the AA can be obtained by combining echo-particle image velocimetry (ePIV) with high frame rate contrast-e ...
This paper presents a power- and area-efficient front-end ASIC that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable the next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography. The 6.1 × 6.1 mm2 AS ...
Purpose: Intraplaque neovascularization (IPN) is an increasingly studied marker of the vulnerable atherosclerotic plaque, and contrast-enhanced ultrasound (CEUS) is an in vivo imaging technique for the assessment of IPN. The purpose of this study was to test novel quantification ...
Ultrafast 3D transesophageal echocardiographic (TEE) imaging, combined with 3D echo particle image velocimetry (ePIV), would be ideal for tracking the complex blood flow patterns in the heart. We are developing a miniature pediatric matrix TEE transducer that employs micro-beamfo ...
In this paper, a programmable time-gain-compensation amplifier dedicated to a 2D piezoelectric ultrasound transducer is presented. It uses an open-loop amplifier structure consisting of a voltage-to-current converter and a current-to-voltage converter. The circuit has been design ...
We consider the scenario of finding the transfer function of an aberrating layer in front of an ultrasound array. We are interested in blindly estimating this transfer function without prior knowledge of the unknown ultrasound sources or ultrasound contrast image. The algorithm g ...
This paper presents a pitch-matched transceiver ASIC integrated with a 2-D transducer array for a wearable ultrasound device for transfontanelle ultrasonography. The ASIC combines 8-fold multiplexing, 4-channel micro-beamforming (μ BF) and sub-array-level digitization to achieve ...