Ionic polymer metal composites (IPMCs) are a class of materials with a rising appeal in biological micro-electromechanical systems (bio-MEMS) due to their unique properties (low voltage output, bio-compatibility, affinity with ionic medium). While tailoring and improving actuation capabilities of IPMCs is a key motivator in almost all IPMC manufacturing reports, very little efforts have been dedicated to sensing using IPMC thinner than 100 µm. Most reports on IPMC manufacturing and utilization rely on 180 µm-thick Nafion with platinum electrodes, too stiff for bio-MEMS applications. The same fabrication process on thinner membranes does yield in very poor electrodes and performance, and needs to be studied to increase flexibility and sensitivity in the microscale range. This study demonstrates an electroless Pt deposition method for fabricating bio-MEMS-suitable 50 µm-thick IPMC samples. First, we perform a comparative study on the platinum distribution within the Nafion backbone as well as on the surface for the standard electroless deposition recipe for thin (50 µm) and thick (180 µm) Nafion. We report strong differences in platinum distribution for thick and thin IPMC that experienced the same manufacturing process. By varying chemical concentrations from the standard recipe we obtain convenient platinum distribution on thin Nafion, with platinum mainly localized in proximity of surface, as well as electrodes with lower sheet resistance. We could measure the flexural rigidity as 3.43 × 10 − 8 N·m2, 46 times lower than standard 180 µm-thick IPMC. The calculated sensitivity is 0.476 ± 0.02 mV mm−1 and the limit of detection for our sensor is 500 ± 20 µm. This procedure sets a milestone for manufacturing 50 µm-thick IPMC for transducers and sensors in bio-MEMS applications.
Sensing flow rates in structured microenvironments like lab-on-chip (LOC) and organ-on-chip (OoC) is crucial to assess important parameters such as transport of media and molecules of interest. So far, these micro-electromechanical systems for biology (bio-MEMS) mostly rely on flow sensing systems based on thermal sensors. However, thermal flow sensing has limitations, since the measurement principle, which is based on generation of heat, can negatively affect the biological system by increasing the fluid temperature above physiological conditions. To overcome this issue, we propose a novel electro-mechanical flow sensor centered around the deformation of a cantilever made of a thin and biocompatible ionic electroactive polymer. The polymer, called ionic polymer metal composite (IPMC), is doped with ions naturally present in most cell media for LOC and OoC devices. Unlike already existing cantilever-based systems which rely on piezo sensitive materials, our IPMC-based flow sensor shows durability in wet environment. We were able to successfully measure pulsatile flow induced by pipetting with flowrate gradually increasing from 10μL/s to 40μL/s. The proposed flow sensor shows good sensing capabilities (4.78 mV/(μL/s)) with a linear behavior in the studied range. This work sets a milestone for using flexible, electroactive materials for sensing applications in delicate biological microenvironments.
delimination of the human tissue
•0.1 % strain has been achieved during the actutaion mode, close to the
strain experienced in vivo by vSMCs
•0.72 V/mm sensitivity has been shown on the sensing mode
•Batch fabrication and downscaling will be targetted in the near future
•Actual sensing of the cells’ contraction will be reserved for further work ...
delimination of the human tissue
•0.1 % strain has been achieved during the actutaion mode, close to the
strain experienced in vivo by vSMCs
•0.72 V/mm sensitivity has been shown on the sensing mode
•Batch fabrication and downscaling will be targetted in the near future
•Actual sensing of the cells’ contraction will be reserved for further work