GL

Guillaume P.R. Lajoinie

info

Please Note

10 records found

A Physically Realistic Contrast-Enhanced Ultrasound Simulator—Part II: Imaging Applications

Journal article (2025) - Baptiste Heiles, Nathan Blanken, Alina Kuliesh, Michel Versluis, Kartik Jain, Guillaume Lajoinie, David Maresca
The development of new imaging paradigms in the field of contrast-enhanced ultrasound (CEUS) is hindered by the difficulty to control complex experimental variables in a laboratory setting, such as vascular geometries, nonlinear ultrasound wave propagation in tissue, or microbubble positions within vessels as a function of time. This development would greatly benefit from the ability to control and reproduce independently these conditions in a simulated environment. Here, we report a physically realistic CEUS simulator, PROTEUS, that generates synthetic contrast-enhanced radio frequency (RF) data. In this article, we show that PROTEUS enables flexible investigations of imaging parameters on CEUS, including innovative transducer architecture, such as row-column addressed arrays, microbubble size distribution, pulse sequences, and vascular geometry. We demonstrate how PROTEUS can emulate various 2-D and 3-D imaging modes, such as pulse inversion (PI) or amplitude modulation (AM), echo particle image velocimetry (PIV), or ultrasound localization microscopy (ULM). Finally, in an investigative simulation case study, we evaluate the impact of microbubble size distribution on ULM on a simulated set of 15000 frames. It is released as an open-source tool for the scientific community. ...

A Physically Realistic Contrast-Enhanced Ultrasound Simulator—Part I: Numerical Methods

Journal article (2024) - Nathan Blanken, Baptiste Heiles, Alina Kuliesh, Michel Versluis, Kartik Jain, David Maresca, Guillaume Lajoinie
Ultrasound contrast agents (UCAs) have been used as vascular reporters for the past 40 years. The ability to enhance vascular features in ultrasound images with engineered lipid-shelled microbubbles has enabled breakthroughs such as the detection of tissue perfusion or super-resolution imaging of the microvasculature. However, advances in the field of contrast-enhanced ultrasound are hindered by experimental variables that are difficult to control in a laboratory setting, such as complex vascular geometries, the lack of ground truth, and tissue nonlinearities. In addition, the demand for large datasets to train deep learning-based computational ultrasound imaging methods calls for the development of a simulation tool that can reproduce the physics of ultrasound wave interactions with tissues and microbubbles. Here, we introduce a physically realistic contrast-enhanced ultrasound simulator (PROTEUS) consisting of four interconnected modules that account for blood flow dynamics in segmented vascular geometries, intravascular microbubble trajectories, ultrasound wave propagation, and nonlinear microbubble scattering. The first part of this study describes the numerical methods that enabled this development. We demonstrate that PROTEUS can generate contrast-enhanced radio-frequency (RF) data in various vascular architectures across the range of medical ultrasound frequencies. PROTEUS offers a customizable framework to explore novel ideas in the field of contrast-enhanced ultrasound imaging. It is released as an open-source tool for the scientific community. ...
Journal article (2022) - Sander Spiekhout, Jason Voorneveld, Benjamin Van Elburg, Guillaume Renaud, Tim Segers, Guillaume P.R. Lajoinie, Michel Versluis, Martin D. Verweij, Nico De Jong, Johannes G. Bosch
Ultrasound (US) contrast agents consist of microbubbles ranging from 1 to 10 μm in size. The acoustical response of individual microbubbles can be studied with high-frame-rate optics or an "acoustical camera"(AC). The AC measures the relative microbubble oscillation while the optical camera measures the absolute oscillation. In this article, the capabilities of the AC are extended to measure the absolute oscillations. In the AC setup, microbubbles are insonified with a high- (25 MHz) and low-frequency US wave (1-2.5 MHz). Other than the amplitude modulation (AM) from the relative size change of the microbubble (employed in Renaud, Bosch, van der Steen, and de Jong (2012a). "An 'acoustical camera' for in vitro characterization of contrast agent microbubble vibrations,"Appl. Phys. Lett. 100(10), 101911, the high-frequency response from individual vibrating microbubbles contains a phase modulation (PM) from the microbubble wall displacement, which is the extension described here. The ratio of PM and AM is used to determine the absolute radius, R0. To test this sizing, the size distributions of two monodisperse microbubble populations (R 0 = 2.1 and 3.5 μm) acquired with the AC were matched to the distribution acquired with a Coulter counter. As a result of measuring the absolute size of the microbubbles, this "extended AC"can capture the full radial dynamics of single freely floating microbubbles with a throughput of hundreds of microbubbles per hour. ...
Journal article (2021) - Josanne S. de Maar, Charis Rousou, Benjamin van Elburg, Hendrik J. Vos, Guillaume P.R. Lajoinie, Clemens Bos, Chrit T.W. Moonen, Roel Deckers
Chemotherapy efficacy is often reduced by insufficient drug uptake in tumor cells. The combination of ultrasound and microbubbles (USMB) has been shown to improve drug delivery and to enhance the efficacy of several drugs in vitro and in vivo, through effects collectively known as sonopermeation. However, clinical translation of USMB therapy is hampered by the large variety of (non-clinical) US set-ups and US parameters that are used in these studies, which are not easily translated to clinical practice. In order to facilitate clinical translation, the aim of this study was to prove that USMB therapy using a clinical ultrasound system (Philips iU22) in combination with clinically approved microbubbles (SonoVue) leads to efficient in vitro sonopermeation. To this end, we measured the efficacy of USMB therapy for different US probes (S5-1, C5-1 and C9-4) and US parameters in FaDu cells. The US probe with the lowest central frequency (i.e. 1.6 MHz for S5-1) showed the highest USMB-induced intracellular uptake of the fluorescent dye SYTOX™ Green (SG). These SG uptake levels were comparable to or even higher than those obtained with a custom-built US system with optimized US parameters. Moreover, USMB therapy with both the clinical and the custom-built US system increased the cytotoxicity of the hydrophilic drug bleomycin. Our results demonstrate that a clinical US system can be used to perform USMB therapy as efficiently as a single-element transducer set-up with optimized US parameters. Therefore, future trials could be based on these clinical US systems, including validated US parameters, in order to accelerate successful translation of USMB therapy. ...
Journal article (2018) - Guillaume Lajoinie, Ying Luan, Erik Gelderblom, Benjamin Dollet, Frits Mastik, Heleen Dewitte, Ine Lentacker, Nico de Jong, Michel Versluis
Journal article (2018) - Tim Segers, Pieter Kruizinga, Maarten P. Kok, Guillaume Lajoinie, Nico De Jong, Michel Versluis
Book chapter (2017) - Guillaume Lajoinie, Nico de Jong, Michel Versluis
High-speed imaging is in popular demand for a broad range of scientific applications, including fluid physics, and bubble and droplet dynamics. It allows for a detailed visualization of the event under study by acquiring a series of images captured at high temporal and spatial resolution. The challenge here is the combination of microscopic length scales and ultrashort time scales associated with the mechanisms governing fluid flows. In this chapter, ultra high-speed imaging at frame rates exceeding 10 million frames per second (fps) is briefly reviewed, including the emerging ultrafast sensor technologies and ultrashort nanoseconds flash illumination techniques. We discuss in detail the design and applications of the Brandaris 128 ultra high-speed imaging facility. The high-speed camera combines the optical frame of a rotating mirror camera with 128 CCD sensors and can record at a maximum frame rate of 25 Mfps. Six acquisitions can be stored in the on-board memory buffer, while in a segmented mode images are acquired in subsets, e.g. 24 x 32 frames, allowing parametric studies to be performed. We also discuss how the Brandaris camera is operated to capture details of bubble dynamics, droplet vaporization, and inkjet printing. ...
Journal article (2017) - Guillaume Lajoinie, Jeong Yu Lee, Joshua Owen, Pieter Kruizinga, Nico De Jong, Gijs Van Soest, Eleanor Stride, Michel Versluis
Photoacoustic (PA) imaging offers several attractive features as a biomedical imaging modality, including excellent spatial resolution and functional information such as tissue oxygenation. A key limitation, however, is the contrast to noise ratio that can be obtained from tissue depths greater than 1-2 mm. Microbubbles coated with an optically absorbing shell have been proposed as a possible contrast agent for PA imaging, offering greater signal amplification and improved biocompatibility compared to metallic nanoparticles. A theoretical description of the dynamics of a coated microbubble subject to laser irradiation has been developed previously. The aim of this study was to test the predictions of the model. Two different types of oil-coated microbubbles were fabricated and then exposed to both pulsed and continuous wave (CW) laser irradiation. Their response was characterized using ultra high-speed imaging. Although there was considerable variability across the population, good agreement was found between the experimental results and theoretical predictions in terms of the frequency and amplitude of microbubble oscillation following pulsed excitation. Under CW irradiation, highly nonlinear behavior was observed which may be of considerable interest for developing different PA imaging techniques with greatly improved contrast enhancement. ...
Journal article (2017) - Guillaume Lajoinie, Erik Linnartz, Pieter Kruizinga, Nico De Jong, Eleanor Stride, Gijs Van Soest, Michel Versluis
Microbubbles are used to enhance the contrast in ultrasound imaging. When coated with an optically absorbing material, these bubbles can also provide contrast in photoacoustic imaging. This multimodal aspect is of pronounced interest to the field of medical imaging. The aim of this paper is to provide a theoretical framework to describe the physical phenomena underlying the photoacoustic response. This article presents a model for a spherical gas microbubble suspended in an aqueous environment and coated with an oil layer containing an optically absorbing dye. The model includes heat transfer between the gas core and the surrounding liquids. This framework is suitable for the investigation of both continuous wave and pulsed laser excitation. This work utilizes a combination of finite difference simulations and numerical integration to determine the dependancy on the physical properties, including composition and thickness of the oil layer on the microbubble response. A normalization scheme for a linearized version of the model was derived to facilitate comparison with experimental measurements. The results show that viscosity and thickness of the oil layer determine whether or not microbubble resonance can be excited. This work also examines the use of non-sinusoidal excitation to promote harmonic imaging techniques to further improve the imaging sensitivity. ...
Journal article (2016) - Ying Luan, Guillaume Renaud, Nico De Jong, Jason L. Raymond, Tim Segers, Guillaume Lajoinie, Robert Beurskens, Frits Mastik, Tom J A Kokhuis, Antonius F W Van Der Steen, Michel Versluis
In this study we present a combined optical sizing and acoustical characterization technique for the study of the dynamics of single freely-floating ultrasound contrast agent microbubbles exposed to long burst ultrasound excitations up to the milliseconds range. A co-axial flow device was used to position individual microbubbles on a streamline within the confocal region of three ultrasound transducers and a high-resolution microscope objective. Bright-field images of microbubbles passing through the confocal region were captured using a high-speed camera synchronized to the acoustical data acquisition to assess the microbubble response to a 1-MHz ultrasound burst. Nonlinear bubble vibrations were identified at a driving pressure as low as 50 kPa. The results demonstrate good agreement with numerical simulations based on the shell-buckling model proposed by Marmottant et al. [J. Acoust. Soc. Am. 118, 3499-3505 (2005)]. The system demonstrates the potential for a high-throughput in vitro characterization of individual microbubbles. ...