Journal article (2025) - Sadaf Soloukey, Luuk Verhoef, Frits Mastik, Michael Brown, Geert Springeling, Bastian S. Generowicz, Djaina D. Satoer, Borbála Hunyadi, Pieter Kruizinga, More authors...
Imagine being able to study the human brain in real-world scenarios while the subject displays natural behaviors such as locomotion, social interaction, or spatial navigation. The advent of ultrafast ultrasound imaging brings us closer to this goal with functional ultrasound imaging (fUSi), a mobile neuroimaging technique. Here, we present real-time fUSi monitoring of brain activity during walking in a subject with a clinically approved sonolucent skull implant. Our approach uses personalized 3D-printed fUSi helmets for stability, optical tracking for cross-modal validation with functional magnetic resonance imaging, advanced signal processing to estimate hemodynamic responses, and facial tracking of a lick licking paradigm. These combined efforts allowed us to show consistent fUSi signals over 20 months, even during high motion activities such as walking. These results demonstrate the feasibility of fUSi for monitoring brain activity in real-world contexts, marking an important milestone for fUSi-based insights in clinical and neuroscientific research. ...
Journal article (2023) - Hongchen Li, Xiufeng Li, Gonzalo Collado-Lara, Kirby R. Lattwein, Frits Mastik, Robert Beurskens, Antonius F.W. van der Steen, Martin D. Verweij, Nico de Jong, Klazina Kooiman
Ultrasound contrast-mediated medical imaging and therapy both rely on the dynamics of micron- and nanometer-sized ultrasound cavitation nuclei, such as phospholipid-coated microbubbles and phase-change droplets. Ultrasound cavitation nuclei respond non-linearly to ultrasound on a nanosecond time scale that necessitates the use of ultra-high-speed imaging to fully visualize these dynamics in detail. In this study, we developed an ultra-high-speed optical imaging system that can record up to 20 million frames per second (Mfps) by coupling two small-sized, commercially available, 10-Mfps cameras. The timing and reliability of the interleaved cameras needed to achieve 20 Mfps was validated using two synchronized light-emitting diode strobe lights. Once verified, ultrasound-activated microbubble responses were recorded and analyzed. A unique characteristic of this coupled system is its ability to be reconfigured to provide orthogonal observations at 10 Mfps. Acoustic droplet vaporization was imaged from two orthogonal views, by which the 3-D dynamics of the phase transition could be visualized. This optical imaging system provides the temporal resolution and experimental flexibility needed to further elucidate the dynamics of ultrasound cavitation nuclei to potentiate the clinical translation of ultrasound-mediated imaging and therapy developments. ...
Journal article (2021) - Reza Pakdaman Zangabad, Johan G. Bosch, Frits Mastik, Robert H.S.H. Beurskens, Vincent A. Henneken, Johannes W. Weekamp, Antonius F.W. van der Steen, Gijs van Soest
Intravascular ultrasound (IVUS) is a well-established diagnostic method that provides images of the vessel wall and atherosclerotic plaques. We investigate the potential for phased-array IVUS utilizing coded excitation (CE) for improving the penetration depth and image signal-to-noise ratio (SNR). It is realized on a new experimental broadband capacitive micromachined ultrasound transducer (CMUT) array, operated in collapse mode, with 96 elements placed at the circumference of a catheter tip with a 1.2- {mm} diameter. We characterized the array performance for CE imaging and showed that the -6-dB device bandwidth at a 30-V dc biasing is 25 MHz with a 20-MHz center frequency, with a transmit sensitivity of 37 kPa/V at that frequency. We designed a linear frequency modulation code to improve penetration depth by compensating for high-frequency attenuation while preserving resolution by a mismatched filter reconstruction. We imaged a wire phantom and a human coronary artery plaque. By assessing the image quality of the reconstructed wire phantom image, we achieved 60- and 70- mu{mathrm {m}} axial resolutions using the short pulse and coded signal, respectively, and gained 8 dB in SNR for CE. Our developed system shows 20-frames/s, pixel-based beam-formed, real-time IVUS images. ...

The Clinical Potential of Intra-Operative Functional and Vascular Brain Mapping

Journal article (2020) - Sadaf Soloukey, Arnaud J.P.E. Vincent, Sebastiaan K.E. Koekkoek, Pieter Kruizinga, Djaina D. Satoer, Frits Mastik, Marion Smits, Clemens M.F. Dirven, Christos Strydis, Johannes G. Bosch, Antonius F.W. van der Steen, Chris I. De Zeeuw
Background and Purpose: Oncological neurosurgery relies heavily on making continuous, intra-operative tumor-brain delineations based on image-guidance. Limitations of currently available imaging techniques call for the development of real-time image-guided resection tools, which allow for reliable functional and anatomical information in an intra-operative setting. Functional ultrasound (fUS), is a new mobile neuro-imaging tool with unprecedented spatiotemporal resolution, which allows for the detection of small changes in blood dynamics that reflect changes in metabolic activity of activated neurons through neurovascular coupling. We have applied fUS during conventional awake brain surgery to determine its clinical potential for both intra-operative functional and vascular brain mapping, with the ultimate aim of achieving maximum safe tumor resection. Methods: During awake brain surgery, fUS was used to image tumor vasculature and task-evoked brain activation with electrocortical stimulation mapping (ESM) as a gold standard. For functional imaging, patients were presented with motor, language or visual tasks, while the probe was placed over (ESM-defined) functional brain areas. For tumor vascular imaging, tumor tissue (pre-resection) and tumor resection cavity (post-resection) were imaged by moving the hand-held probe along a continuous trajectory over the regions of interest. Results: A total of 10 patients were included, with predominantly intra-parenchymal frontal and temporal lobe tumors of both low and higher histopathological grades. fUS was able to detect (ESM-defined) functional areas deep inside the brain for a range of functional tasks including language processing. Brain tissue could be imaged at a spatial and temporal resolution of 300 μm and 1.5–2.0 ms respectively, revealing real-time tumor-specific, and healthy vascular characteristics. Conclusion: The current study presents the potential of applying fUS during awake brain surgery. We illustrate the relevance of fUS for awake brain surgery based on its ability to capture both task-evoked functional cortical responses as well as differences in vascular characteristics between tumor and healthy tissue. As current neurosurgical practice is still pre-dominantly leaning on inherently limited pre-operative imaging techniques for tumor resection-guidance, fUS enters the scene as a promising alternative that is both anatomically and physiologically informative. ...
Journal article (2020) - Inés Beekers, Frits Mastik, Robert Beurskens, Phoei Ying Tang, Merel Vegter, Antonius F.W. van der Steen, Nico de Jong, Martin D. Verweij, Klazina Kooiman
Ultrasound insonification of microbubbles can locally enhance drug delivery, but the microbubble–cell interaction remains poorly understood. Because intracellular calcium (Cai 2+) is a key cellular regulator, unraveling the Cai 2+ fluctuations caused by an oscillating microbubble provides crucial insight into the underlying bio-effects. Therefore, we developed an optical imaging system at nanometer and nanosecond resolution that can resolve Cai 2+ fluctuations and microbubble oscillations. Using this system, we clearly distinguished three Cai 2+ uptake profiles upon sonoporation of endothelial cells, which strongly correlated with the microbubble oscillation amplitude, severity of sonoporation and opening of cell–cell contacts. We found a narrow operating range for viable drug delivery without lethal cell damage. Moreover, adjacent cells were affected by a calcium wave propagating at 15 μm/s. With the unique optical system, we unraveled the microbubble oscillation behavior required for drug delivery and Cai 2+ fluctuations, providing new insight into the microbubble–cell interaction to aid clinical translation. ...
Conference paper (2020) - Bas Generowicz, Luuk Verhoef, Frits Mastik, Stefanie Dijkhuizen, Nikki van Dorp, Jason Voorneveld, Johannes Bosch, Karishma Kumar, Geert Leus, More Authors...
Power Doppler (PD) imaging has become a staple in high frame rate ultrasound imaging due to its ability to image small vessels and slow-moving flows, such as in the case of imaging blood flow in the brain. Alternatively, color Doppler (CD) can be used to determine the one-dimensional directional information of the blood scatterers. This can help determine if the flow is arterial or venous, or distinguish between adjacent flows that have an opposite direction. Current methods for estimating 2D blood velocity vectors rely mostly on trigonometric solutions using synthetic apertures or, large plane-wave angles in transmission and sub-apertures in receive to be able to resolve the 2D vector. Relative to PD or CD techniques, these methods are more computationally expensive and have not been successfully used to image blood flow direction within micrometer sized vasculature. In this paper, we propose to use the orientations of the vessels derived from a directional spatial filter in combination with the CD signal to enhance the PD images with directional information. This approach was tested on simulated data as well as on a 2D image containing brain vasculature of a mouse. ...
Journal article (2020) - Inés Beekers, Merel Vegter, Kirby R. Lattwein, Frits Mastik, Robert Beurskens, Antonius F.W. van der Steen, Nico de Jong, Martin D. Verweij, Klazina Kooiman
Ultrasound insonification of microbubbles can locally increase vascular permeability to enhance drug delivery. To control and optimize the therapeutic potential, we need to better understand the underlying biological mechanisms of the drug delivery pathways. The aim of this in vitro study was to elucidate the microbubble-endothelial cell interaction using the Brandaris 128 ultra-high-speed camera (up to 25 Mfps) coupled to a custom-built Nikon confocal microscope, to visualize both microbubble oscillation and the cellular response. Sonoporation and opening of cell-cell contacts by single αVβ3-targeted microbubbles (n = 152) was monitored up to 4 min after ultrasound insonification (2 MHz, 100–400 kPa, 10 cycles). Sonoporation occurred when microbubble excursion amplitudes exceeded 0.7 μm. Quantification of the influx of the fluorescent model drug propidium iodide upon sonoporation showed that the size of the created pore increased for larger microbubble excursion amplitudes. Microbubble-mediated opening of cell-cell contacts occurred as a cellular response upon sonoporation and did not correlate with the microbubble excursion amplitude itself. The initial integrity of the cell-cell contacts affected the susceptibly to drug delivery, since cell-cell contacts opened more often when cells were only partially attached to their neighbors (48%) than when fully attached (14%). The drug delivery outcomes were independent of nonlinear microbubble behavior, microbubble location, and cell size. In conclusion, by studying the microbubble–cell interaction at nanosecond and nanometer resolution the relationship between drug delivery pathways and their underlying mechanisms was further unraveled. These novel insights will aid the development of safe and efficient microbubble-mediated drug delivery. ...
Journal article (2019) - Sophinese Iskander-Rizk, Min Wu, Geert Springeling, Heleen M.M. van Beusekom, Frits Mastik, Maaike te Lintel Hekkert, Robert H.S.H. Beurskens, Antonius F.W. van der Steen, Gijs van Soest, More Authors...
Prospective identification of lipid-rich vulnerable plaque has remained an elusive goal. Intravascular photoacoustics, a hybrid optical and ultrasonic technology, was developed as a tool for lipid-rich plaque imaging. Here, we present the first in vivo images of lipid-rich coronary atherosclerosis acquired with this new technology in a large animal model, and relate them to independent catheter-based imaging and histology. ...
Journal article (2019) - Tianshi Wang, Tom Pfeiffer, Joost Daemen, Frits Mastik, Wolfgang Wieser, A. F.W. Van Der Steen, Robert Huber, Gijs Van Soest
We demonstrate megahertz intravascular Doppler Optical Coherence Tomography (OCT). The OCT system relies on a 1.1 mm diameter motorized catheter and a 1.5 MHz Fourier Domain Mode Locked (FDML) laser. By resolving the phase shift between adjoint A-lines, the flow pattern image can be reconstructed. Imaging experiments were carried out in swine coronary artery in vitro at a speed of 600 frames/s. The MHz sweep rate not only allows us to investigate flow velocity of up to 37.5 cm/s without phase-unwrapping, but also enables dynamic flow imaging at high frame rate. ...
Journal article (2019) - Inés Beekers, Kirby R. Lattwein, Joop J.P. Kouijzer, Simone A.G. Langeveld, M. Vegter, Robert Beurskens, F. Mastik, Rogier Verduyn Lunel, Antonius F.W. van der Steen, Nico de Jong
Controlling microbubble-mediated drug delivery requires the underlying biological and physical mechanisms to be unraveled. To image both microbubble oscillation upon ultrasound insonification and the resulting cellular response, we developed an optical imaging system that can achieve the necessary nanosecond temporal and nanometer spatial resolutions. We coupled the Brandaris 128 ultra-high-speed camera (up to 25 million frames per second) to a custom-built Nikon A1R+ confocal microscope. The unique capabilities of this combined system are demonstrated with three experiments showing microbubble oscillation leading to either endothelial drug delivery, bacterial biofilm disruption, or structural changes in the microbubble coating. In conclusion, using this state-of-the-art optical imaging system, microbubble-mediated drug delivery can be studied with high temporal resolution to resolve microbubble oscillation and high spatial resolution and detector sensitivity to discern cellular response. Combining these two imaging technologies will substantially advance our knowledge on microbubble behavior and its role in drug delivery. ...
Journal article (2019) - Sophinese Iskander-Rizk, Pieter Kruizinga, Robert Beurskens, Geert Springeling, Frits Mastik, Natasja M.S. de Groot, Paul Knops, Antonius F.W. van der Steen, Gijs van Soest
In interventional electrophysiology, catheter-based radiofrequency (RF) ablation procedures restore cardiac heart rhythm by interrupting aberrant conduction paths. Real-time feedback on lesion formation and post-treatment lesion assessment could overcome procedural challenges related to ablation of underlying structures and lesion gaps. This study aims to evaluate real-time visualization of lesion progression and continuity during intra-atrial ablation with photoacoustic (PA) imaging, using clinically deployable technology. A PA-enabled RF ablation catheter was used to ablate and illuminate porcine left atrium, both excised and intact in a passive beating heart ex-vivo, for photoacoustic signal generation. PA signals were received with an intracardiac echography catheter. Using the ratio of PA images acquired with excitation wavelengths of 790 nm and 930 nm, ablation lesions were successfully imaged through circulating saline and/or blood, and lesion gaps were identified in real-time. PA-based assessment of RF-ablation lesions was successful in a realistic preclinical model of atrial intervention. ...
Journal article (2018) - Guillaume Lajoinie, Ying Luan, Erik Gelderblom, Benjamin Dollet, Frits Mastik, Heleen Dewitte, Ine Lentacker, Nico de Jong, Michel Versluis
Journal article (2018) - Jovana Janjic, Pieter Kruizinga, Pim van der Meulen, Geert Springeling, Frits Mastik, Geert Leus, Johan G. Bosch, Antonius F.W. van der Steen, Gijs van Soest
We present a form of acoustic microscopy, called Structured Ultrasound Microscopy (SUM). It creates a volumetric image by recording reflected echoes of ultrasound waves with a structured phase front using a moving single-element transducer and computational reconstruction. A priori knowledge of the acoustic field produced by the single element allows us to relate the received echoes to a 3D scatter map within the acoustic beam itself, leading to an isotropic resolution at all depths. An aberration mask in front of the acoustic element imposes the phase structure, broadening the beam and breaking the spatial coherence between different voxels at equal acoustic propagation delay, increasing the uniqueness of the reconstruction. By translating the transducer across the 3D volume, we synthetically enlarge the imaging aperture by using multiple overlapping and spatially sparsely sampled measurements to solve for the entire image. In this paper, we explain the SUM technique and demonstrate microscopic imaging at 20 MHz of a 2.3 × 2.3 × 1.2 mm object in water, with an isotropic resolution below 100 μm. The proposed approach allows for wide-field 3D imaging at isotropic microscopic resolution using a small unfocused ultrasound sensor and multiple spatially sparsely sampled measurements. This technique may find applications in many other fields where space is constrained, device simplicity is desired, and wide-field isotropic high-resolution imaging is required. ...
Conference paper (2018) - Sophinese Iskander-Rizk, Min Wu, Geert Springeling, Frits Mastik, Robert H.S.H. Beurskens, Antonius F.W. Van Der Steen, Gijs Van Soest
Intravascular photoacoustic/ultrasound imaging (IVPA/US) can image the structure and composition of atherosclerotic lesions identifying lipid-rich plaques ex vivo and in vivo. In the literature, multiple IVPA/US catheter designs were presented and validated both in ex-vivo models and preclinical in-vivo situations. Since the catheter is a critical component of the imaging system, we discuss here a catheter design oriented to imaging plaque in a realistic and translatable setting. We present a catheter optimized for light delivery, manageable flush parameters and robustness with reduced mechanical damage risks at the laser/catheter joint interface. We also show capability of imaging within sheath and in water medium. ...
Journal article (2018) - Richard Rau, Pieter Kruizinga, Frits Mastik, Markus Belau, Nico de Jong, Johannes G. Bosch, Wolfgang Scheffer, Georg Maret
Recent advances in ultrasound Doppler imaging have facilitated the technique of functional ultrasound (fUS) which enables visualization of brain-activity due to neurovascular coupling. As of yet, this technique has been applied to rodents as well as to human subjects during awake craniotomy surgery and human newborns. Here we demonstrate the first successful fUS studies on awake pigeons subjected to auditory and visual stimulation. To allow successful fUS on pigeons we improved the temporal resolution of fUS up to 20,000 frames per second with real-time visualization and continuous recording. We show that this gain in temporal resolution significantly increases the sensitivity for detecting small fluctuations in cerebral blood flow and volume which may reflect increased local neural activity. Through this increased sensitivity we were able to capture the elaborate 3D neural activity pattern evoked by a complex stimulation pattern, such as a moving light source. By pushing the limits of fUS further, we have reaffirmed the enormous potential of this technique as a new standard in functional brain imaging with the capacity to unravel unknown, stimulus related hemodynamics with excellent spatiotemporal resolution with a wide field of view. ...
Conference paper (2018) - Jovana Janjic, Awaz Ali, Frits Mastik, Merel D. Leistikow, Johan G. Bosch, Paul Breedveld, Antonius F.W. Van Der Steen, Gijs Van Soest
In interventional cardiology catheters are routinely used to access and treat defects and diseases in the heart. Image guidance using forward-looking (FL)ultrasound transducers at the tip of the catheter could give the physician visual feedback during complex procedures such as valve replacement or transseptal puncture. In this work, we investigate FL 3D imaging by integrating a 7 MHz single-element ultrasound transducer at the tip of a novel multi-steerable intracardiac catheter together with an optical shape sensing fiber (OSS). We tested the imaging capability of the integrated device on an ex-vivo pig heart. By acquiring ultrasound A-lines at different locations while steering the catheter tip, a sparse 3D image is obtained. To reconstruct a volumetric image from the sparse data we implemented an adaptive Normalized Convolution (NC)algorithm were the dimension, orientation and angle of the 3D anisotropic kernel changes dynamically according to the scanning path. We acquired ultrasound A-lines of the tricuspid valve and we computed the 3D image using NC with both an isotropic kernel and an anisotropic kernel. We successfully interpolated the sparse data obtaining 3D volumes of the heart. By using an anisotropic kernel better 3D reconstruction is achieved with higher detail information compared to the reconstruction obtained using an isotropic kernel. This pilot experiment demonstrates the potential of FL image guidance during intracardiac procedures using a single-element transducer integrated in a steerable catheter with an OSS fiber. ...
Journal article (2017) - Pieter Kruizinga, Pim van der Meulen, Frits Mastik, Nico de Jong, Johannes G. Bosch, Geert Leus
Most techniques that are used to reconstruct images from raw ultrasound signals are based on pre-defined geometrical processing. This type of image reconstruction typically has a low computational complexity and allows for real-time visualization. Since these techniques do not account for situation-specific parameters such as transducer characteristics and medium in-homogeneities, they cannot make proper use of the information that is contained in the raw ultrasound signals. In this paper, we explore the possibility of reconstructing images that best explain the measured ultrasound signals given the full ultrasound propagation model including all parameters. We build this model by measuring the spatiotemporal impulse response of the imaging transducer and, using the angular spectrum approach, estimate the ultrasound signal as it would originate from each individual image pixel position. An iterative search for the pixel combination that best explains the recorded signals provides the final image. We discuss the details of this model, provide experimental proof that this reconstruction allows for improved image quality, and extend our ideas to other imaging schemes such as compressive imaging. ...
Journal article (2017) - Min Wu, Geert Springeling, Matija Lovrak, Frits Mastik, Sophinese Iskander-Rizk, Tianshi Wang, Heleen M.M. Van Beusekom, A. F.W. Van Der Steen, Gijs Van Soest
Lipid deposition can be assessed with combined intravascular photoacoustic/ultrasound (IVPA/US) imaging. To date, the clinical translation of IVPA/US imaging has been stalled by a low imaging speed and catheter complexity. In this paper, we demonstrate imaging of lipid targets in swine coronary arteries in vivo, at a clinically useful frame rate of 20 s−1. We confirmed image contrast for atherosclerotic plaque in human samples ex vivo. The system is on a mobile platform and provides real-time data visualization during acquisition. We achieved an IVPA signal-to-noise ratio of 20 dB. These data show that clinical translation of IVPA is possible in principle. ...
Abstract (2017) - Pieter Kruizinga, Pim van der Meulen, Frits Mastik, Andrejs Fedjajevs, Geert Springeling, Nico de Jong, Geert Leus, Johannes G. Bosch
3D ultrasound (US) requires expensive transducers comprising thousands of elements and complicated hardware. This complexity originates from the classical idea on spatial sampling requirements for US imaging. The discovery of compressive sensing allows to ease this sampling constraint, enabling smarter ways of recording the required information. Inspired by this work we introduce a US imager that can perform 3D imaging using one acoustic sensor. Our device sends and detects US waves through a random coding mask that enables unique signals at every voxel. Rotation of the mask allows for several compressed measurements. By knowing the voxel signals, a full 3D reconstruction of the object can be obtained, as we demonstrate in this work. ...
Journal article (2017) - Klazina Kooiman, Tom van Rooij, Bin Qin, Frits Mastik, Hendrik J. Vos, Michel Versluis, Alexander L. Klibanov, Nico De Jong, Flordeliza S. Villanueva, Xucai Chen
Acoustic behavior of lipid-coated microbubbles has been widely studied, which has led to several numerical microbubble dynamics models that incorporate lipid coating behavior, such as buckling and rupture. In this study we investigated the relationship between micro-bubble acoustic and lipid coating behavior on a nanosecond scale by using fluorescently labeled lipids. It is hypothesized that a local increased concentration of lipids, appearing as a focal area of increased fluorescence intensity (hot spot) in the fluorescence image, is related to buckling and folding of the lipid layer thereby highly influencing the microbubble acoustic behavior. To test this hypothesis, the lipid microbubble coating was fluorescently labeled. The vibration of the microbubble (n= 177; 2.3-10.3 μm in diameter) upon insonification at an ultrasound frequency of 0.5 or 1 MHz at 25 or 50 kPa acoustic pressure was recorded with the UPMC Cam, an ultra-high-speed fluorescence camera, operated at ∼4-5 million frames per second. During short tone-burst excitation, hot spots on the microbubble coating occurred at relative vibration amplitudes > 0.3 irrespective of frequency and acoustic pressure. Around resonance, the majority of the microbubbles formed hot spots. When the microbubble also deflated acoustically, hot spot formation was likely irreversible. Although compression-only behavior (defined as substantially more microbubble compression than expansion) and subharmonic responses were observed in those microbubbles that formed hot spots, both phenomena were also found in microbubbles that did not form hot spots during insonification. In conclusion, this study reveals hot spot formation of the lipid monolayer in the microbubble's compression phase. However, our experimental results show that there is no direct relationship between hot spot formation of the lipid coating and microbubble acoustic behaviors such as compression-only and the generation of a subharmonic response. Hence, our hypothesis that hot spots are related to acoustic buckling could not be verified. ...