Single-Sided Ultrasound Imaging of the Bone Cortex

Anatomy, Tissue Characterization and Blood Flow

In this chapter, we first review the reasons why conventional ultrasonography fails to image the interior of bones. Next we show our recent work on imaging a cortical bone layer with ultrasound. Revealing the shape of the cortex of a bone, in particular its thickness, is of inter ...

Erratum: Lamb Waves and Adaptive Beamforming for Aberration Correction in Medical Ultrasound Imaging

Lamb Waves and Adaptive Beamforming for Aberration Correction in Medical Ultrasound Imaging (IEEE Trans.Ultrason., Ferroelectr., Freq. Control, early access (2020) DOI: 10.1109/TUFFC.2020.3007345)

In the above article [1], we mentioned that the superposition of the different symmetric (S) modes in the frequencywavenumber (f-k) domain results in a high-intensity region where its slope corresponds to the longitudinal wave speed in the slab. However, we have recently understo ...
Decreased thickness of the bone cortex due to bone loss in the course of ageing and osteoporosis is associated with reduced bone strength. Cortical thickness measurement from ultrasound images was recently demonstrated in young adults. This requires the identification of both the ...

Corrigendum to “Non-linear Response and Viscoelastic Properties of Lipid-Coated Microbubbles

DSPC versus DPPC” (Ultrasound Med Biol 2015;41:1432–1445) (Non-linear Response and Viscoelastic Properties of Lipid-Coated Microbubbles: DSPC versus DPPC 41(5) (1432–1445), (S0301562915000356), (10.1016/j.ultrasmedbio.2015.01.004))

The authors regret that there was a mistake in reporting the mol% of the microbubble coating composition used. For all experiments, the unit in mg/mL was used and the conversion mistake occurred only when converting to mol% to define the ratio between the coating formulation comp ...

Corrigendum to “Non-linear Response and Viscoelastic Properties of Lipid-Coated Microbubbles

DSPC versus DPPC” (Ultrasound Med Biol 2015;41:1432–1445) (Non-linear Response and Viscoelastic Properties of Lipid-Coated Microbubbles: DSPC versus DPPC 41(5) (1432–1445), (S0301562915000356), (10.1016/j.ultrasmedbio.2015.01.004))

The authors regret that there was a mistake in reporting the mol% of the microbubble coating composition used. For all experiments, the unit in mg/mL was used and the conversion mistake occurred only when converting to mol% to define the ratio between the coating formulation comp ...

Corrigendum to “Non-linear Response and Viscoelastic Properties of Lipid-Coated Microbubbles

DSPC versus DPPC” (Ultrasound Med Biol 2015;41:1432–1445) (Non-linear Response and Viscoelastic Properties of Lipid-Coated Microbubbles: DSPC versus DPPC 41(5) (1432–1445), (S0301562915000356), (10.1016/j.ultrasmedbio.2015.01.004))

The authors regret that there was a mistake in reporting the mol% of the microbubble coating composition used. For all experiments, the unit in mg/mL was used and the conversion mistake occurred only when converting to mol% to define the ratio between the coating formulation comp ...
Transcranial ultrasound imaging (TUI) is a diagnostic modality with numerous applications, but unfortunately, it is hindered by phase aberration caused by the skull. In this article, we propose to reconstruct a transcranial B-mode image with a refraction-corrected synthetic apert ...
Intraosseous blood circulation is thought to have a critical role in bone growth and remodeling, fracture healing, and bone disorders. However, it is rarely considered in clinical practice because of the absence of a suitable noninvasive in vivo measurement technique. In this wor ...
Transcranial ultrasound imaging is a suitable technology for diagnosis of strokes as it is safe, portable, relatively inexpensive and available in emergency medicine services, however it currently offers poor image quality due to the phase aberration caused by the human skull. In ...
While transcranial ultrasound imaging is a promising diagnostic modality, it is still hindered due to phase aberration and multiple scattering caused by the skull. In this paper, we compare near-field phase-screen modeling (PS) to a geometry-based phase aberration correction tech ...
We present a technique called photoacoustic vector-flow (PAVF) to quantify the speed and direction of flowing optical absorbers at each pixel from acoustic-resolution PA images. By varying the receiving angle at each pixel in post-processing, we obtain multiple estimates of the p ...
Ultrasound (US) contrast agents consist of microbubbles ranging from 1 to 10 μm in size. The acoustical response of individual microbubbles can be studied with high-frame-rate optics or an "acoustical camera"(AC). The AC measures the relative microbubble oscillation while the opt ...
By changing the ultrasonic receiving angle in post-processing, we can obtain flow vectors from a photoacoustic experiment on a blood vessel phantom by solving the photoacoustic Doppler equation using a least-squares optimisation approach.@en