CB

Claus Leth Bak

info

Please Note

3 records found

Journal article (2025) - Zhaoxin Wang, Xing Wei, Claus Leth Bak, Filipe Faria da Silva, Tianming Luo, Weichuan Zhao, Peter Vaessen, Henrik Sorensen, Mohamad Ghaffarian Niasar
As the voltage levels of solid-state transformers (SSTs) increase using medium-voltage switches, high-frequency transformers (HFTs) used inside SSTs are subjected to increased electrical stress. This stress, characterized by high voltage, high-frequency pulsewidth modulation (PWM) voltage, can cause insulation partial discharge (PD) and potentially lead to failure of the HFT insulation system. While PD behavior under power-frequency sinusoidal voltage has been extensively studied, the behavior of HFT insulation under PWM square pulse conditions is less well understood. To address this gap, a high voltage high-frequency PWM voltage PD test platform is developed and high-frequency current transformer (HFCT) and ultra-high-frequency (UHF) antenna are used for PD signal detection. PD tests are performed under a variety of PWM conditions including PWM frequency, rise time, voltage amplitude, and different insulation layers to thoroughly investigate the HFT insulation behavior. The PD characteristics of repetitive PD inception voltage and phase-resolved PD patterns at different PWM conditions are recorded and analyzed under PWM conditions. In addition, this article explores the underlying PD mechanisms of the HFT insulation under high-frequency PWM stress, providing insights to explain the observed test results. The findings from this research provide essential references and lay a solid foundation for future advances in optimal design, health monitoring, reliability analysis, and lifetime prediction for HFTs in power electronics applications. ...
Journal article (2025) - Zhengfa Zhang, Filipe Faria da Silva, Yifei Guo, Yufei Xi, Claus Leth Bak, Jose Rueda Torres, Jin Dong, Zhe Chen, Yilu Liu
The increasing integration of renewable-based distributed generation (DG) brings growing challenges to distribution network (DN) voltage control. To address this issue, a two-stage distributed online voltage control framework (TDO-VC) is proposed in this paper. In the proposed method, legacy voltage control devices are controlled in the upper stage on an hourly timescale, while DGs operate autonomously online in the lower stage to remove instantaneous voltage violations. The idea of receding horizon control is applied in the upper stage to comprehensively consider the current and future renewable generation, and the generalized fast dual ascent (Gf-DA) is employed in the lower stage to effectively manage DGs through near real-time optimization. The effectiveness of the proposed TDO-VC is demonstrated by rigorous theoretical analysis and case studies on IEEE-123 bus system. ...
Journal article (2020) - Arcadio Perilla , José Luis Rueda Torres, Elyas Rakhshani, Roni Irnawan, Filipe Faria da Silva, Mart van der Meijden, Claus Leth Bak, Alex Alefragkis, Anna Lindefelt
This study presents an investigation of the impact of the quasi-stationary voltage support provided by a voltage source converter (VSC) connected to a single point of a power system. Based on the directional derivative concept, an analytical method is developed to quantify the sensitivities of the AC bus voltage with respect to the VSC reactive power control modes. Based on a real case study, it is shown that the method applies to VSC units that are part of VSC-HVDC systems, which can operate in a point-to-point or multi-terminal configuration. Time-domain simulations are performed to verify the findings from the application of the analytical method on a reduced size power system. ...