Computational Ultrasound Carotid Artery Imaging with a Few Transceivers
An Emulation Study
Ultrasonography could allow operator-independent examination and continuous monitoring of the carotid artery (CA) but normally requires complex and expensive transducers, especially for 3-D. By employing computational ultrasound imaging (cUSi), using an aberration mask and model-based reconstruction, a monitoring device could be constructed with a more affordable simple transducer design comprising only a few elements. We aim to apply the cUSi concept to create a CA monitoring system. The system’s possible configurations for the 2-D imaging case were explored using a linear array setup emulating a cUSi device in silico, followed by in vitro testing and in vivo CA imaging. Our study shows enhanced reconstruction performance with the use of an aberrating mask, improved lateral resolution through proper choice of the mask delay variation, and more accurate reconstructions using least-squares with QR (LSQR) decomposition compared to matched filtering (MF). Together, these advancements enable B-mode reconstruction and power Doppler imaging (PDI) of the CA with sufficient quality for monitoring using a configuration of 12 transceivers coupled with a random aberration mask with a maximum delay variation of four wave periods (WPs).
Four-dimensional ultrasound imaging of complex biological systems such as the brain is technically challenging because of the spatiotemporal sampling requirements. We present computational ultrasound imaging (cUSi), an imaging method that uses complex ultrasound fields that can be generated with simple hardware and a physical wave prediction model to alleviate the sampling constraints. cUSi allows for high-resolution four-dimensional imaging of brain hemodynamics in awake and anesthetized mice.
Compressive Imaging with Spatial Coding Masks on Low Number of Elements
An Emulation Study
We intend to develop an ultrasound compressive imaging device to perform carotid artery (CA) function and flow monitoring/imaging by using just a few single element transducers equipped with spatial coding masks. The spatially unique impulse responses can be exploited in compressive reconstructions. To explore the potential of different configurations, in this study we emulated such a device using a linear array system. We combined its elements with individual digital delays into a small number of groups. The results suggest our spatial coding mask approach based on reconstructions regularized with a least squares method has potential for CA monitoring with only 10 to 12 sensors.