AL

A.C. Laan

info

Please Note

8 records found

Combination of therapies is a common strategy in cancer treatment. Such combined therapies only have merit provided that there is superior therapeutic outcome with fewer side effects, compared to single therapies. Here, this work explores the possibility to combine chemotherapy with radionuclide therapy using polymeric micelles as a delivery vehicle. For this purpose, this work prepares poly(ε-caprolactone-b-ethylene oxide) (PCL-PEO) micelles and load them simultaneously with paclitaxel (PTX) and 177Lu(III). This work chooses a 3D tumor spheroid composed of glioblastoma cells (U87) to evaluate the combined treatment. The diffusion of the micelles in the spheroid is investigated by confocal laser scanning microscopy (CLSM) and light-sheet fluorescence microscopy (LSFM). The results show that the micelles are able to penetrate deep into the spheroid within 24 h of incubation and mainly accumulated around or in the lysosomes once in the cell. Subsequently, this work evaluates the cell killing efficiency of the single treatments (PTX or 177Lu(III)) versus combined treatment (PTX + 177Lu(III)) by measuring the growth of the spheroids as well as by performing a cell-viability assay. The results indicate that the combined therapy achieves a superior therapeutic outcome with better cell growth inhibition and cell killing efficiency compared to the single treatments. ...
A variety of polymer micelles are designed for the delivery of chemotherapeutic drugs to tumors. Although the promise of these nanocarriers is very high, in the clinic the effectivity is rather limited. Determining the in vivo fate of the micelles can greatly help to improve this treatment. Here, a simple and fast chelator-free method for radiolabeling of polymer micelles composed of different block copolymers is presented, which can allow evaluating the behavior of the nanocarriers in vivo using noninvasive nuclear imaging techniques (e.g., single photon computed tomography, SPECT). The radiolabeling method consists of adding the radioisotope ions, i.e., 111In(III), resulting in a high radiolabeling efficiencies up to 90%. The results suggest that the radiolabeling efficiency depends on two important factors: the properties of the hydrophobic block in the block copolymer composing the micelle core, and the speciation of the radiometal salts. The formation of metal hydroxides and their precipitation in the core of the micelles appears to be a key factor for high stability. Moreover, the method can be applied to radiolabel the micelles in the presence of chemotherapeutic drugs. Finally, a SPECT study shows that the radiolabeled samples are stable in vivo without any evident loss of 111In(III). ...
Polymeric micelles, due to their easy preparation and versatile properties, have been widely applied as one of the most popular carriers for chemotherapeutic agents. Such micelles primarily prevent the leakage of drugs during transportation and thus protect healthy tissue. Controlled drug release, which releases the drugs at the site of interest using internal or external stimuli as triggers, can further improve the safety of the drug delivery process. In this paper, we investigate whether ionizing radiation can be used to initiate release, focusing on using Cerenkov light as a possible trigger. For this purpose, micelles composed of the degradable polymer poly(ϵ-caprolactone-b-ethylene glycol) (PCL-PEO) were first loaded with the photosensitizer chlorin e6 (Ce6) and subsequently exposed to gamma or X-ray radiation of varying radiation doses. The results reveal that Ce6 was released from the micelles under radiation, regardless of the energy of incident photons, showing that Cerenkov light was not the driving force behind the observed release. SANS measurements showed that the volume fraction of the micelles containing Ce6 was reduced after exposure to radiation. This change in volume fraction suggests that the number of micelles was reduced, which was probably responsible for the release of Ce6. The exact mechanism, however, remains unclear. Subsequently, the PCL-PEO micelles were loaded with Ce6 and one of the following drugs: doxorubicin (Dox), docetaxel (DTX), and paclitaxel (PTX). Under radiation exposure, Dox, which is quite stable in single-loaded micelles, shows an enhanced release profile in the presence of Ce6, while DTX and PTX remained in the micelles, regardless of the presence of Ce6. ...
A great number of fluorescent probes have been developed for detecting singlet oxygen (1O2), which is considered to be one of the most effective reactive oxygen species (ROS), especially in clinical applications. The commercially available fluorescent probe Singlet Oxygen Sensor Green (SOSG) is widely used due to its reported high selectivity to 1O2. In this study, we carried out systemic experiments to determine the activation of SOSG in the presence of ionizing radiation. The results show that the SOSG probe exhibits a pronounced fluorescence increase as a function of radiation dose delivered by gamma-rays as well as X-rays, in conditions where the formation of singlet oxygen is not expected. Furthermore, scavenger tests indicate that hydroxyl radicals may be involved directly or indirectly in the activation process of SOSG although the exact mechanism remains unknown. ...

The technique of choice for the characterization of polymeric nanocarriers

Journal article (2017) - Adrianus C. Laan, Antonia G. Denkova
This letter is meant to make scientists aware of the proper application of transmission electron microscopy (TEM) for the assessment of polymeric self-assemblies. Cryogenic (cryo)-TEM should be the method of choice. Here, we show the difference in morphologies observed in the same sample when using cryo-TEM and when using TEM with drying, demonstrating the importance of choosing the proper method. ...
Journal article (2016) - L. Jennings, O. Ivashchenko, I. J C Marsman, A. C. Laan, A. G. Denkova, G. Waton, F. J. Beekman, F. Schosseler, E. Mendes
Understanding how nanoparticle properties such as size, morphology and rigidity influence their circulation time and biodistribution is essential for the development of nanomedicine therapies. Herein we assess the influence of morphology on cellular internalization, in vivo biodistribution and circulation time of nanocarriers using polystyrene-b-poly(ethylene oxide) micelles of spherical or elongated morphology. The glassy nature of polystyrene guarantees the morphological stability of the carriers in vivo and by encapsulating Indium-111 in their core, an assessment of the longitudinal in vivo biodistribution of the particles in healthy mice is performed with single photon emission computed tomography imaging. Our results show prolonged blood circulation, longer than 24 hours, for all micelle morphologies studied. Dynamics of micelle accumulation in the liver and other organs of the reticuloendothelial system show a size-dependent nature and late stage liver clearance is observed for the elongated morphology. Apparent contradictions between recent similar studies can be resolved by considering the effects of flexibility and degradation of the elongated micelles on their circulation time and biodistribution. ...
Journal article (2016) - Adrianus C. Laan, Costanza Santini, Laurence Jennings, Marion de Jong, Monique R. Bernsen, Antonia G. Denkova
Background: Single photon emission computed tomography (SPECT) is an indispensable tool in the determination of the in vivo fate of polymeric micelles. However, for this purpose, the micelles need to be radiolabeled, and almost all radiolabeling procedures published to date involve the conjugation of a chelating agent to the constituting polymer, which could actually affect their biodistribution. In this paper, we report a new facile method for radiolabeling polystyrene-b-poly(ethylene oxide) diblock copolymer micelles without the necessity of any chemical modification. Instead, we entrap the radiolabel (i.e., 111In) in the micellar core during the formation of the micelles by using tropolone as lipophilic ligand. Methods: Micelles were prepared by emulsifying a polymer solution in chloroform with a buffer containing 111In and lipophilic ligand tropolone, by stirring for about 2 h. The produced micelles were physically characterized by means of dynamic light scattering and transmission electron microscopy. The biological properties of the radiolabeled micelles were determined by means of in vivo and ex vivo evaluation. SPECT analysis was done on Balb/c-nu mice, after administration of 1 mg micelles containing 22 MBq of 111In. SPECT images were obtained over 24 h. Biodistribution of the micelles was assessed also ex vivo. Results: The radiolabeling method is robust and reproducible with constant radiolabeling efficiency (~30 %) even at indium concentrations that are much higher than the necessary for in vivo studies, and the radiolabel retention is more than 80 % in mouse serum at 48 h. Radiolabeled micelles having hydrodynamic radius of 97 ± 13 nm have been successfully evaluated in vivo and ex vivo in non-tumor-bearing mice, revealing significant blood circulation up to at least 24 h post injection, with low accumulation in most organs except for the liver and spleen, which are the natural organs for clearance of nanoparticles. Conclusions: An easy and robust radiolabeling method has been developed, and its applicability is demonstrated in animal studies, showing its value for future investigation of polymeric micelles as nanocarriers in tumor-bearing mice. ...
Journal article (2016) - L. Jennings, P. Glazer, A. C. Laan, R. M. De Kruijff, G. Waton, F. Schosseler, E. Mendes
We present an approach which makes it possible to directly determine the bending modulus of single elongated block copolymer micelles. This is done by forming arrays of suspended micelles onto microfabricated substrates and by performing three-point bending flexural tests, using an atomic force microscope, on their suspended portions. By coupling the direct atomic force microscopy measurements with differential scanning calorimetry data, we show that the presence of a crystalline corona strongly increases the modulus of the copolymer elongated micelles. This large increase suggests that crystallites in the corona are larger and more uniformly oriented due to confinement effects. Our findings together with this hypothesis open new interesting avenues for the preparation of core-templated polymer fibres with enhanced mechanical properties. ...