Sd

Sander den Hoedt

info

Please Note

2 records found

Master thesis (2019) - Bas Bikker, Murali Ghatkesar, Sander den Hoedt
Plunge freezing is used as a sample preparation method to freeze biological samples in a vitrified thin water layer of <500nm. Typically sample is loaded on thin (<10nm) carbon membranes of a copper mesh grid. The vitrified biological sample is imaged using high resolution cryogenic transmission electron microscopy (Cryo-EM).The common practice of rapidly plunge freezing biological material prepares it to be placed in the vacuum chamber of the Cryo-EM by cooling it to a vitrified state (causing vitrification). In the present sample preparation methods, 90% of the biological materials used experience some form of contamination or damage during the transfer process and end up unusable. While improvements have been made, such as the automation of sample loading into the Cyro-EM, these improvements have brought on their own set of complications. In want of a better solution for the issues surrounding the cryo-sample preparation and loading, the research and experiments of this thesis focused on the question: is it possible for biological material to be vitrified on an Autogrid with plunge freezing? To answer this question experiments were carried out to measure the cooling rate of EM-grid and Autogrids during plunge freezing with a Vitrobot. A small thermocouple was embedded into an EM standard-grid and Autogrid glued in place with cryo-varnish. The EM-grid was then mounted onto Vitrobot tweezers and plunged into liquid ethane (cryogen). The set-up mimics to the best of its possibilities the same conditions and procedure of the standard Cyro-EM workflow and temperature was recorded at a rate of 32000 samples per second. Cooling rates measured with an EM-grid were as expected. The cooling rate of the Autogrid is slower than that of standard grid, which implies that the Vitrobot is not capable of vitrifying biological materials on an Autogrid. Research and experiments showed that the Vitrobot would probably not be capable of achieving vitrification on Autogrid because the measured cooling rate was slower then that of EM-grid. Cooling rates with the Vitrobot could be improved by a faster and deeper plunger. ...
Master thesis (2019) - Xuanmin He, Sander den Hoedt, Jo Spronck, Murali Ghatkesar, Hassan Hossein Nia Kani
The Nobel Prize in Chemistry in 2017 went to the development of cryo-electron microscopy, which contributed to the discovery of new cells and viruses, the diagnosis of unknown diseases, the mapping of human genomes and the manufacturing of semiconductors. Cryo Correlative light and electron microscopy (Cryo-CLEM), is the combination of using fluorescence microscopy and cryo-electron microscopy to image cryo-immobilized bio-samples. These samples (at a temperature lower than −165ᵒC), require critical conditions in preparation and preservation to prevent contamination and heating which have a negative influence on the imaging results. In the current sample transfer workflow, almost 90% of the samples transferred end up being wasted due to the unideal protection and transfer gap. Therefore, an integrated high-vacuum sample transfer system which fits the interfaces of CLEM devices and actively protects the samples from heating and contamination in transfer has been designed to conquer the problems, ensure better imaging results, and increase the process yield. COMSOL simulations on its thermal and mechanical behaviors have been carried out to theoretically verify and iterate the design. The new transfer system provides a cheaper, faster, easier, more contamination-free, more temperature-stable, more user-friendly workflow that can increase the yield of sample transfer from 10% to 90%. ...