Circular Image

T. Horeman

92 records found

Background: Laparoscopic surgery requires a complex set of motor skills. Currently, basic laparoscopic skills training is performed in a static environment, while intraoperatively, abdominal tissue is often moving. The aim of this study was to develop a dynamic training platform ...

Transitioning towards a circular (healthcare) economy

Circular Economy principles, leadership, policy and decision-making

This book offers a comprehensive roadmap toward a circular and sustainable healthcare system, structured into three distinct parts.

Part I describes circular principles and policy tactics. Chapter 1 outlines the essentials of sustainable healthcare and designates the par ...
Objective: Central venous catheters (CVCs) provide direct access to the central circulatory system, commonly used in hemodialysis and intensive care units for drug administration. Although uncertified for the procedure, CVCs are sometimes used for power injection of contrast medi ...
Background: Technological innovations have significantly enhanced the objective assessment of technical skills in minimally invasive surgery, offering substantial potential for proficiency-based training. However, the integration of these innovative tools into surgical education ...

Shaping global health

The indispensable role of biomedical engineers

Modern medical science stands at the crossroads of technology, precision and innovation. An enormous variety of technological marvels proliferate in modern medical practice, which many take for granted, such as ultrasound, CT and MRI imaging, portable sensors, implants of almost ...
Background: Totally extraperitoneal (TEP) inguinal hernia surgery is a commonly performed but technically challenging procedure with a long learning curve. As TEP can be executed using two different trocar placements: a midline or a triangular configuration, the question remains ...
Since the introduction of robot-assisted laparoscopic surgery, efforts have been made to incorporate force sensing technologies to monitor critical components and to provide force feedback. The advanced laparoscopic robotic system (AdLap RS) is a robotic platform that aims to mak ...
Objective: Cemented total hip arthroplasty (THA) demonstrates superior survival rates compared to uncemented procedures. Nevertheless, most younger patients opt for uncemented THA, as removing well-fixed bone cement in the femur during revisions is complex, particularly the dista ...
Collision feedback about instrument and environment interaction is often lacking in robotic surgery training devices. The PoLaRS virtual reality simulator is a newly developed desk trainer that overcomes drawbacks of existing robot trainers for advanced laparoscopy. This study ai ...

The SATA-Drive

A Modular Robotic Drive for Reusable Steerable Laparoscopic Instruments

Introduction: Most robotic instruments and their drives still risk residual contamination due to cleaning complexities, rendering them limited reusable, and tend to have larger instruments than the 5mm laparoscopic standard. The novel steerable laparoscopic SATA-LRS uses modulari ...
Objective: Hemodialysis patients usually receive an arteriovenous fistula (AVF) in the arm as vascular access conduit to allow dialysis 2-3 times a week. This AVF introduces the high flow necessary for dialysis, but over time the ever-present supraphysiological flow is the leadin ...
Surgeons performing robotic-assisted laparoscopic surgery experience physical stress and overuse of shoulder muscles due to sub-optimal arm support during surgery. The objective is to present a novel design and prototype of a dynamic arm support for robotic laparoscopic surgery t ...

“O.R. GOES GREEN”

A first step toward reducing our carbon footprint in the operating room and hospital

Hospitals in Europe produce approximately 6 million tons of medical waste annually, about one-third of this originating in operating rooms. Most of it is solid waste, which can be recycled if bodily fluids do not contaminate it. Only 2–3% of hospital waste must be disposed of as ...
In de afgelopen decennia is het aantal medische wegwerpproducten significant toegenomen. Binnen het bedrijf GreenCycl en het GreenCycl Fieldlab worden oplossingen gezocht om de schaarste van grondstoffen tegen te gaan. Diverse methoden zijn onderzocht om medisch afval na gebruik ...
Background: During minimal access surgery, surgical smoke is produced which can potentially be inhaled by the surgical team, leading to several health risks. This smoke can escape from the abdominal cavity into the operating room due to trocar leakage. The trocars and insufflator ...
Mechanical stress influences scarring of a surgical wound. Several lines have been proposed for the best excision direction. It is unknown if these lines still apply when the body posture changes. The objective is to measure the skin reaction force in four directions and determin ...
Background: During laparoscopic surgery, CO2 insufflation gas could leak from the intra-abdominal cavity into the operating theater. Medical staff could therefore be exposed to hazardous substances present in leaked gas. Although previous studies have shown that leakag ...
Introduction: Robot-assisted surgery is often performed by experienced laparoscopic surgeons. However, this technique requires a different set of technical skills and surgeons are expected to alternate between these approaches. The aim of this study is to investigate the crossove ...
Background:
Veress needles (VN) are commonly used in establishing pneumoperitoneum in laparoscopic surgery. Previously, a VN with a new safety mechanism ‘VeressPLUS’ needle (VN+) was developed to reduce the amount of overshoot.

Methods:
Eighteen participants (n ...
Introduction: Based on the success of the former “Shaft-Actuated, Tip-Articulated” SATA-Drive, a prototype robotic instrument driver for modular, steerable, laparoscopic instruments, a new driver is designed and tested to improve previously lacking features concerning cleanabilit ...