SR

S.B. Raghunathan

info

Please Note

9 records found

Journal article (2018) - D. Bera, S.B. Raghunathan, Hans Bosch, C. Chen, Z. Chen, M.A.P. Pertijs, M.D. Verweij, V. Daeichin, H.J. Vos, A.F.W. van der Steen, N. de Jong
Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (>200 Hz). To address these issues, we have recently developed a prototype miniaturized matrix transducer for pediatric patients with micro-beamforming and a small central transmitter. In this paper we propose two multiline parallel 3D beamforming techniques (μBF25 and μBF169) using the micro-beamformed datasets from 25 and 169 transmit events to achieve volume rates of 300 Hz and 44 Hz, respectively. Both the realizations use angle-weighted combination of the neighboring overlapping sub-volumes to avoid artifacts due to sharp intensity changes introduced by parallel beamforming. In simulation, the image quality in terms of the width of the point spread function (PSF), lateral shift invariance and mean clutter level for volumes produced by μBF25 and μBF169 are similar to the idealized beamforming using a conventional single-line acquisition with a fully-sampled matrix transducer (FS4k, 4225 transmit events). For completeness, we also investigated a 9 transmit-scheme (3 × 3) that allows even higher frame rates but found worse B-mode image quality with our probe. The simulations were experimentally verified by acquiring the μBF datasets from the prototype using a Verasonics V1 research ultrasound system. For both μBF169 and μBF25, the experimental PSFs were similar to the simulated PSFs, but in the experimental PSFs, the clutter level was ∼10 dB higher. Results indicate that the proposed multiline 3D beamforming techniques with the prototype matrix transducer are promising candidates for real-time pediatric 3D TEE. ...
Journal article (2018) - Verya Daeichin, Deep Bera, Martin Verweij, More authors..., Shreyas Raghunathan, Maysam Shabani Motlagh, Zhao Chen, Chao Chen, Emile Noothout, Hendrik J. Vos, Michiel Pertijs, Nico de Jong
This paper presents the design, fabrication and characterization of a miniature PZT-on-CMOS matrix transducer for real-time pediatric 3-dimensional (3D) transesophageal echocardiography (TEE). This 3D TEE probe consists of a 32 × 32 array of PZT elements integrated on top of an Application Specific Integrated Circuit (ASIC). We propose a partitioned transmit/receive array architecture wherein the 8 × 8 transmitter elements, located at the centre of the array, are directly wired out and the remaining receive elements are grouped into 96 sub-arrays of 3 × 3 elements. The echoes received by these sub-groups are locally processed by micro-beamformer circuits in the ASIC that allow pre-steering up to ±37°. The PZT-on-CMOS matrix transducer has been characterized acoustically and has a centre frequency of 5.8 MHz, -6 dB bandwidth of 67%, a transmit efficiency of 6 kPa/V at 30 mm, and a receive dynamic range of 85 dB with minimum and maximum detectable pressures of 5 Pa and 84 kPa respectively. The properties are very suitable for a miniature pediatric real-time 3D TEE probe. ...
Journal article (2017) - Chao Chen, Zhao Chen, Johan G. Bosch, Martin D. Verweij, Nico De Jong, Michiel A.P. Pertijs, Deep Bera, Shreyas B. Raghunathan, Maysam Shabanimotlagh, Emile Noothout, Zu-Yao Chang, Jacco Ponte, Christian Prins, Hendrik J. Vos
This paper presents a power-and area-efficient front-end application-specific integrated circuit (ASIC) that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography. The 6.1 × 6.1 mm2 ASIC, implemented in a low-voltage 0.18-μm CMOS process, effectively reduces the number of receive (RX) cables required in the probe's narrow shaft by ninefold with the aid of 96 delay-and-sum beamformers, each of which locally combines the signals received by a sub-array of 3 × 3 elements. These beamformers are based on pipeline-operated analog sample-and-hold stages and employ a mismatch-scrambling technique to prevent the ripple signal associated with the mismatch between these stages from limiting the dynamic range. In addition, an ultralow-power low-noise amplifier architecture is proposed to increase the power efficiency of the RX circuitry. The ASIC has a compact element matched layout and consumes only 0.27 mW/channel while receiving, which is lower than the state-of-the-art circuit. Its functionality has been successfully demonstrated in 3-D imaging experiments. ...
Conference paper (2017) - Maysam Shabanimotlagh, Verya Daeichin, Shreyas B. Raghunathan, Pieter Kruizinga, Hendrik J. Vos, Johannes G. Bosch, Michiel Pertijs, Nico De Jong, Martin Verweij
Over the last decade, clinical studies show a strong interest in real-time 3D imaging. This calls for ultrasound probes with high-element-count 2D matrix transducer arrays. These may be interfaced to an imaging system using an in-probe Application Specific Integrated Circuit (ASIC) that takes care of signal amplification, element switching, sub-array beamforming, etc. Since the ASIC is made from silicon and is mounted directly behind the transducer elements, it can acoustically be regarded as a rigid plate that can sustain traveling lateral waves. These waves lead to acoustical cross-talk between the elements, and results in extra peaks in the directivity pattern. We propose two solutions to this problem, based on numerical simulations. One approach is to decrease the phase velocity in the silicon by reducing the silicon thickness and absorbing the energy using a proper backing material. Another solution is to disturb the waves inside the silicon plate by sub-dicing the back-side of the ASIC. We conclude that both solutions can be used to improve the directivity pattern. ...
Abstract (2017) - M. Shabanimotlagh, S. Raghunathan, D. Bera, Zhao Chen, Chao Chen, V. Daeichin, M. Pertijs, J.G. Bosch, N. de Jong, M. Verweij
Echocardiography is a portable, safe, and low-cost imaging technique for accurate assessment of the heart. In transesophageal echocardiography (TEE) the esophagus is utilized as the imaging window to examine the cardiac anatomy and function. In conventional TEE probes, a one-dimensional (1D) ultrasound array is employed to obtain two-dimensional (2D) cross-sectional images of the heart. Since cardiac morphology, leakage of valves and function of the outflow tracts are all three-dimensional (3D) phenomena, it is beneficial to interpret them from 3D images. Therefore, there is high clinical demand for matrix TEE probes that are capable of providing real-time volumetric images [1]. Several matrix arrays (Philips X7-2t, Siemens V5M TEE, General Electric 6VTD) have been developed for this purpose, however all of them are large in size (~10 cm3) and uncomfortable to use on non-anesthetized patients [2]. We aim to develop a matrix TEE probe with a small head volume (<1 cm3), which is suitable for long term monitoring of cardiac system on adults and in babies. We have developed a prototype of a small matrix TEE probe, which consists of a piezoelectric matrix transducer directly mounted on an Application Specific Integrated Circuit (ASIC). The ASIC performs the task of micro-beamforming, signal amplification and efficient data reduction. The piezoelectric matrix array consist of a 32×32 PZT elements with a pitch of 150 μm × 150 μm. The transmit aperture consists of 8×8 elements at the centre of the array, which are directly wired out to the ultrasound system. The remaining 864 elements are used in receive and are organized in 96 sub-arrays of 3×3 elements to reduce the cable count with a factor of 9. The signals from the individual elements in a sub-array are combined to a single output signal using a micro-beamformer on the ASIC. The micro-beamformer allows pre-steering of 0◦, ±17◦, and ±37◦ angles in both lateral and elevation directions. By recording datasets for different pre-steering angles, and by processing and combining them, a large volume image can be constructed. Acoustic performance of the prototype is evaluated in a water tank. The transmit transfer function of a single element is measured by applying a 20 cycle sinusoidal voltage, sweeping from 3 to 8 MHz with steps of 50 kHz. The output pressure is recorded by a calibrated hydrophone. It is found that the transducer has a central frequency of 5 MHz, a bandwidth of 40% and a transmit efficiency of 6.4 kPa/V (at 51 mm). To characterize the micro-beamforming function, three delay angles of 0◦, 17◦ and 37◦ were programmed. While transmitting with a well-defined external source, the output voltage from a sub-group was recorded from -50◦ to +50◦ degrees. We observe that the theoretical values of the beam profile agree well with the measurement results, especially with regard to the position of the grating lobes and side lobes. ...
Conference paper (2016) - C. Chen, Z. Chen, J. G. Bosch, M. D. Verweij, N. De Jong, M. A P Pertijs, D. Bera, S. B. Raghunathan, M. Shabanimotlagh, E. Noothout, Z.Y. Chang, J. Ponte, C. Prins, H. J. Vos
This paper presents a power- and area-efficient front-end ASIC that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable the next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography. The 6.1 × 6.1 mm2 ASIC, implemented in a low-voltage 0.18 μm CMOS process, effectively reduces the number of cables required in the probe's narrow shaft by means of 96 sub-array beamformers, which have a compact element-matched layout and employ mismatch-scrambling to enhance the dynamic range. The ASIC consumes less than 230 mW while receiving and its functionality has been successfully demonstrated in a 3-D imaging experiment. ...
Conference paper (2016) - D. Bera, H. J. Vos, S. B. Raghunathan, C. Chen, Z. Chen, M.D. Verweij, M.A.P. Pertijs, N. de Jong, J.G. Bosch
A general challenge in 3D volumetric imaging is the large channel count. One solution uses integrated microbeamformers. The reconstruction of the entire volume from these micro-beamformed datasets can be performed in many ways. In this paper we propose two 3D multiline beamforming techniques, suitable for producing volumes at high frame rate and compare the image qualities to a fully-sampled matrix. The performance of the proposed beamforming techniques was evaluated with simulations in FieldII. Results show that the proposed simple volume reconstruction technique (using 25 transmissions) produces volumes at very high frame rate, but with sharp intensity changes within the volume. The proposed advanced technique (using 169 transmissions) produces volumes very similar to a fully-sampled matrix transducer despite the micro-beamforming. ...
Conference paper (2016) - Maysam Shabanimotlagh, Jovana Janjic, Shreyas Raghunathan, Michiel A P Pertijs, Nico De Jong, Martin Verweij
Accurate diagnostics of stenosis and blood flow distribution in carotid arteries requires transducers capable of producing 3D volume images with high frame rate for real time imaging. In the process of designing a matrix probe, an important goal is to realize the acoustic stack with high sensitivity and bandwidth. In this study, we employ a finite element analysis to evaluate the effect of sub-dicing on the performance of an acoustic stack in a piezoelectric matrix array. The array is integrated with an Application Specific Integrated Circuit (ASIC), which performs the task of signal amplification and efficient data reduction. The results show that two sub-dicing cuts can improve the sensitivity by 40%, bandwidth by 20%, and reduce the ringing time by 43%, which are all desired for improving the image quality. ...