S.B. Raghunathan
Please Note
9 records found
1
Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (>200 Hz). To address these issues, we have recently developed a prototype miniaturized matrix transducer for pediatric patients with micro-beamforming and a small central transmitter. In this paper we propose two multiline parallel 3D beamforming techniques (μBF25 and μBF169) using the micro-beamformed datasets from 25 and 169 transmit events to achieve volume rates of 300 Hz and 44 Hz, respectively. Both the realizations use angle-weighted combination of the neighboring overlapping sub-volumes to avoid artifacts due to sharp intensity changes introduced by parallel beamforming. In simulation, the image quality in terms of the width of the point spread function (PSF), lateral shift invariance and mean clutter level for volumes produced by μBF25 and μBF169 are similar to the idealized beamforming using a conventional single-line acquisition with a fully-sampled matrix transducer (FS4k, 4225 transmit events). For completeness, we also investigated a 9 transmit-scheme (3 × 3) that allows even higher frame rates but found worse B-mode image quality with our probe. The simulations were experimentally verified by acquiring the μBF datasets from the prototype using a Verasonics V1 research ultrasound system. For both μBF169 and μBF25, the experimental PSFs were similar to the simulated PSFs, but in the experimental PSFs, the clutter level was ∼10 dB higher. Results indicate that the proposed multiline 3D beamforming techniques with the prototype matrix transducer are promising candidates for real-time pediatric 3D TEE.
This paper presents the design, fabrication and characterization of a miniature PZT-on-CMOS matrix transducer for real-time pediatric 3-dimensional (3D) transesophageal echocardiography (TEE). This 3D TEE probe consists of a 32 × 32 array of PZT elements integrated on top of an Application Specific Integrated Circuit (ASIC). We propose a partitioned transmit/receive array architecture wherein the 8 × 8 transmitter elements, located at the centre of the array, are directly wired out and the remaining receive elements are grouped into 96 sub-arrays of 3 × 3 elements. The echoes received by these sub-groups are locally processed by micro-beamformer circuits in the ASIC that allow pre-steering up to ±37°. The PZT-on-CMOS matrix transducer has been characterized acoustically and has a centre frequency of 5.8 MHz, -6 dB bandwidth of 67%, a transmit efficiency of 6 kPa/V at 30 mm, and a receive dynamic range of 85 dB with minimum and maximum detectable pressures of 5 Pa and 84 kPa respectively. The properties are very suitable for a miniature pediatric real-time 3D TEE probe.
This paper presents a power-and area-efficient front-end application-specific integrated circuit (ASIC) that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography. The 6.1 × 6.1 mm2 ASIC, implemented in a low-voltage 0.18-μm CMOS process, effectively reduces the number of receive (RX) cables required in the probe's narrow shaft by ninefold with the aid of 96 delay-and-sum beamformers, each of which locally combines the signals received by a sub-array of 3 × 3 elements. These beamformers are based on pipeline-operated analog sample-and-hold stages and employ a mismatch-scrambling technique to prevent the ripple signal associated with the mismatch between these stages from limiting the dynamic range. In addition, an ultralow-power low-noise amplifier architecture is proposed to increase the power efficiency of the RX circuitry. The ASIC has a compact element matched layout and consumes only 0.27 mW/channel while receiving, which is lower than the state-of-the-art circuit. Its functionality has been successfully demonstrated in 3-D imaging experiments.
Over the last decade, clinical studies show a strong interest in real-time 3D imaging. This calls for ultrasound probes with high-element-count 2D matrix transducer arrays. These may be interfaced to an imaging system using an in-probe Application Specific Integrated Circuit (ASIC) that takes care of signal amplification, element switching, sub-array beamforming, etc. Since the ASIC is made from silicon and is mounted directly behind the transducer elements, it can acoustically be regarded as a rigid plate that can sustain traveling lateral waves. These waves lead to acoustical cross-talk between the elements, and results in extra peaks in the directivity pattern. We propose two solutions to this problem, based on numerical simulations. One approach is to decrease the phase velocity in the silicon by reducing the silicon thickness and absorbing the energy using a proper backing material. Another solution is to disturb the waves inside the silicon plate by sub-dicing the back-side of the ASIC. We conclude that both solutions can be used to improve the directivity pattern.
Accurate diagnostics of stenosis and blood flow distribution in carotid arteries requires transducers capable of producing 3D volume images with high frame rate for real time imaging. In the process of designing a matrix probe, an important goal is to realize the acoustic stack with high sensitivity and bandwidth. In this study, we employ a finite element analysis to evaluate the effect of sub-dicing on the performance of an acoustic stack in a piezoelectric matrix array. The array is integrated with an Application Specific Integrated Circuit (ASIC), which performs the task of signal amplification and efficient data reduction. The results show that two sub-dicing cuts can improve the sensitivity by 40%, bandwidth by 20%, and reduce the ringing time by 43%, which are all desired for improving the image quality.