MV

Michel Versluis

info

Please Note

18 records found

Journal article (2025) - Sander Spiekhout, Yuchen Wang, Tim Segers, Klazina Kooiman, Michel Versluis, Jason Voorneveld, Nico de Jong, Johannes G. Bosch
Objective
The response of ultrasound contrast agents is sensitive to ambient pressure, especially via their scattered subharmonic signal, which makes them a promising candidate for non-invasive pressure measurements in vivo. This work aimed to understand the sensitivity to ambient pressure of subharmonic oscillations from single microbubbles.

Methods
The subharmonic oscillation amplitude of single microbubbles in response to varying ambient pressure was studied both experimentally and numerically. In experiment, approximately 2200 single microbubbles from a monodisperse population were measured at a driving frequency close to twice their resonance frequency.

Results
The results of the numerical simulations and experiments show that a pressure change leads to a small size change in the bubble that then changes the lipid packing density, and with that the stiffness of the bubble shell.

Conclusion
The dependency of subharmonic oscillation amplitude to changes in ambient pressure can be explained by a shift in the resonance frequency of the bubble as a function of ambient pressure. The subharmonic response increases with ambient pressure when the resonance frequency shifts toward half the driving frequency and decreases when the resonance frequency shifts away from half the driving frequency. These findings help to understand non-invasive pressure sensing through subharmonic ultrasound imaging. ...
Journal article (2024) - Sander Spiekhout, Benjamin van Elburg, Jason Voorneveld, Nico de Jong, Michel Versluis, Johannes G. Bosch, Tim Segers
Phospholipid-coated microbubbles with a uniform acoustic response are a promising avenue for functional ultrasound sensing. A uniform acoustic response requires both a monodisperse size distribution and uniform viscoelastic shell properties. Monodisperse microbubbles can be produced in a microfluidic flow focusing device. Here, we investigate whether such monodisperse microbubbles have uniform viscoelastic shell properties and thereby a uniform “mono-acoustic” response. To this end, we visualized phase separation of the DSPC and DPPE-PEG5000 lipid shell components and measured the resonance curves of nearly 2000 single and freely floating microbubbles using a high-frequency acoustic scattering technique. The results demonstrate inhomogeneous phase-separated shell microdomains across the monodisperse bubble population, which may explain the measured inhomogeneous viscoelastic shell properties. The shell viscosity varied over an order of magnitude and the resonance frequency by a factor of two indicating both a variation in shell elasticity and in initial surface tension despite the relatively narrow size distribution. ...
Journal article (2022) - Sander Spiekhout, Jason Voorneveld, Benjamin Van Elburg, Guillaume Renaud, Tim Segers, Guillaume P.R. Lajoinie, Michel Versluis, Martin D. Verweij, Nico De Jong, Johannes G. Bosch
Ultrasound (US) contrast agents consist of microbubbles ranging from 1 to 10 μm in size. The acoustical response of individual microbubbles can be studied with high-frame-rate optics or an "acoustical camera"(AC). The AC measures the relative microbubble oscillation while the optical camera measures the absolute oscillation. In this article, the capabilities of the AC are extended to measure the absolute oscillations. In the AC setup, microbubbles are insonified with a high- (25 MHz) and low-frequency US wave (1-2.5 MHz). Other than the amplitude modulation (AM) from the relative size change of the microbubble (employed in Renaud, Bosch, van der Steen, and de Jong (2012a). "An 'acoustical camera' for in vitro characterization of contrast agent microbubble vibrations,"Appl. Phys. Lett. 100(10), 101911, the high-frequency response from individual vibrating microbubbles contains a phase modulation (PM) from the microbubble wall displacement, which is the extension described here. The ratio of PM and AM is used to determine the absolute radius, R0. To test this sizing, the size distributions of two monodisperse microbubble populations (R 0 = 2.1 and 3.5 μm) acquired with the AC were matched to the distribution acquired with a Coulter counter. As a result of measuring the absolute size of the microbubbles, this "extended AC"can capture the full radial dynamics of single freely floating microbubbles with a throughput of hundreds of microbubbles per hour. ...

DSPC versus DPPC” (Ultrasound Med Biol 2015;41:1432–1445) (Non-linear Response and Viscoelastic Properties of Lipid-Coated Microbubbles: DSPC versus DPPC 41(5) (1432–1445), (S0301562915000356), (10.1016/j.ultrasmedbio.2015.01.004))

Journal article (2021) - Tom van Rooij, Ying Luan, Guillaume Renaud, Antonius F.W. van der Steen, Michel Versluis, Nico de Jong, Klazina Kooiman
The authors regret that there was a mistake in reporting the mol% of the microbubble coating composition used. For all experiments, the unit in mg/mL was used and the conversion mistake occurred only when converting to mol% to define the ratio between the coating formulation components. The correct molecular weight of PEG-40 stearate is 2046.54 g/mol (Shen et al. 2008; Kilic and Bolukcu 2018), not 328.53 g/mol. On page 1433, the sentence should read “The lipid coating was composed of 84.8 mol% DSPC (P6517, Sigma-Aldrich, Zwijndrecht, Netherlands) or DPPC (850355, Avanti Polar Lipids, Alabaster, AL, USA); 8.2 mol% polyoxyethylene-40-stearate (PEG40 stearate, P3440, Sigma-Aldrich); 5.9 mol% 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-[carboxy(polyethylene glycol)2000 (DSPE-PEG2000, 880125, Avanti Polar Lipids); and 1.1 mol% 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-[biotinyl(polyethylene glycol)-2000] (DSPE-PEG2000-biotin) (880129, Avanti Polar Lipids).” This correction does not change the conclusions published in this work. The authors apologize for any inconvenience caused. ...
Journal article (2018) - Guillaume Lajoinie, Ying Luan, Erik Gelderblom, Benjamin Dollet, Frits Mastik, Heleen Dewitte, Ine Lentacker, Nico de Jong, Michel Versluis
Journal article (2018) - Ines Beekers, Tom van Rooij, Martin D. Verweij, Michel Versluis, Nico de Jong, Sebastiaan J. Trietsch, Klazina Kooiman
Conference paper (2018) - Astrid M. Hoving, Jason Voorneveld, Evelien E. De Vries, Erik Groot Jebbink, Michel Versluis, Johan G. Bosch, Nico De Jong, Julia Mikhal, Gert J. De Borst, Cornelis H. Slump
Introduction: To improve carotid artery stenting (CAS), more information about the functioning of the stent is needed. Therefore, a method that can image the flow near and around a stent is required. The aim of this study was to evaluate the performance of high-frame-rate contrast-enhanced ultrasound (HFR CEUS) in the presence of a stent. Methodology: HFR CEUS acquisitions of a carotid artery phantom, a silicone tube with diameter 8 mm, with and without a stent were acquired at transmit voltages of 2V, 4V and 10V using a Verasonics ultrasound system and C5-2 probe. Different concentrations of ultrasound contrast agent (UCA) were tested in a blood mimicking fluid (BMF). Particle image velocimetry (PIV) analysis was performed on Singular Value Decomposition (SVD) filtered images. Mean and peak velocities, and correlation coefficients were compared between stented and non-stented regions. Also, experimental results were compared with theoretical and numerical models. Results: The averaged experimental mean velocity (0.113 m/s) was significant lower than the theoretical and numerical mean velocity (0.129 m/s). The averaged experimental peak velocity (0.152 m/s) was significant lower than the theoretical and numerical peak velocity (0.259 m/s). Correlation coefficients and averaged mean velocity values were lower (difference of 0.022 m/s) in stented regions compared to non-stented regions. Conclusion: In vitro experiments showed an underestimation of mean and peak velocities in stented regions compared to non-stented regions. However, the microbubbles can be tracked efficiently and the expected laminar flow profile can be quantified using HFR CEUS near and around a stent. ...
Journal article (2018) - Tim Segers, Pieter Kruizinga, Maarten P. Kok, Guillaume Lajoinie, Nico De Jong, Michel Versluis
Journal article (2018) - Stefan Engelhard, Jason Voorneveld, Erik Groot Jebbink, Hendrik J. Vos, Jos J.M. Westenberg, Frank J.H. Gijsen, Pavel Taimr, Michel Versluis, Nico De Jong, Johan G. Bosch, Michel M.P.J. Reijnen
Purpose: To study the feasibility of high-frame-rate (HFR) contrast material-enhanced (CE) ultrasound particle image velocimetry (PIV), or echo PIV, in the abdominal aorta. Materials and Methods: Fifteen healthy participants (six men; median age, 23 years [age range, 18-34 years]; median body mass index, 20.3 kg/m2 [range, 17.3-24.9 kg/m2]) underwent HFR CE US. US microbubbles were injected at incremental doses (0.25, 0.5, 0.75, and 1.5 mL), with each dose followed by US measurement to determine the optimal dosage. Different US mechanical index values were evaluated (0.09, 0.06, 0.03, and 0.01) in a diverging wave acquisition scheme. PIV analysis was performed via pairwise cross-correlation of all captured images. Participants also underwent phase-contrast MRI. The echo PIV and phase-contrast MRI velocity profiles were compared via calculation of similarity index and relative difference in peak velocity. Results: Visualization of the aortic bifurcation with HFR CE US was successful in all participants. Optimal echo PIV results were achieved with the lowest contrast agent dose of 0.25 mL in combination with the lowest mechanical indexes (0.01 or 0.03). Substantial bubble destruction occurred at higher mechanical indexes (>0.06). Flow patterns were qualitatively similar in the echo PIV and MR images. The echo PIV and MRI velocity profiles showed good agreement (similarity index, 0.98 and 0.99; difference in peak velocity, 8.5% and 17.0% in temporal and spatial profiles, respectively). Conclusion: Quantification of blood ow in the human abdominal aorta with US particle image velocimetry (echo PIV) is feasible. Use of echo PIV has potential in the clinical evaluation of aortic disease. ...
Book chapter (2017) - Guillaume Lajoinie, Nico de Jong, Michel Versluis
High-speed imaging is in popular demand for a broad range of scientific applications, including fluid physics, and bubble and droplet dynamics. It allows for a detailed visualization of the event under study by acquiring a series of images captured at high temporal and spatial resolution. The challenge here is the combination of microscopic length scales and ultrashort time scales associated with the mechanisms governing fluid flows. In this chapter, ultra high-speed imaging at frame rates exceeding 10 million frames per second (fps) is briefly reviewed, including the emerging ultrafast sensor technologies and ultrashort nanoseconds flash illumination techniques. We discuss in detail the design and applications of the Brandaris 128 ultra high-speed imaging facility. The high-speed camera combines the optical frame of a rotating mirror camera with 128 CCD sensors and can record at a maximum frame rate of 25 Mfps. Six acquisitions can be stored in the on-board memory buffer, while in a segmented mode images are acquired in subsets, e.g. 24 x 32 frames, allowing parametric studies to be performed. We also discuss how the Brandaris camera is operated to capture details of bubble dynamics, droplet vaporization, and inkjet printing. ...
Journal article (2017) - Tom J A Kokhuis, Benno A. Naaijkens, Lynda J.M. Juffermans, Otto Kamp, Antonius F.W. Van Der Steen, Michel Versluis, Nico De Jong
The use of stem cells for regenerative tissue repair is promising but hampered by the low number of cells delivered to the site of injury. To increase the delivery, we propose a technique in which stem cells are linked to functionalized microbubbles, creating echogenic complex dubbed StemBells. StemBells are highly susceptible to acoustic radiation force which can be employed after injection to push the StemBells locally to the treatment site. To optimally benefit from the delivery technique, a thorough characterization of the dynamics of StemBells during ultrasound exposure is needed. Using high-speed optical imaging, we study the dynamics of StemBells as a function of the applied frequency from which resonance curves were constructed. A theoretical model, based on a modified Rayleigh-Plesset type equation, captured the experimental resonance characteristics and radial dynamics in detail. ...
Journal article (2017) - Klazina Kooiman, Tom van Rooij, Bin Qin, Frits Mastik, Hendrik J. Vos, Michel Versluis, Alexander L. Klibanov, Nico De Jong, Flordeliza S. Villanueva, Xucai Chen
Acoustic behavior of lipid-coated microbubbles has been widely studied, which has led to several numerical microbubble dynamics models that incorporate lipid coating behavior, such as buckling and rupture. In this study we investigated the relationship between micro-bubble acoustic and lipid coating behavior on a nanosecond scale by using fluorescently labeled lipids. It is hypothesized that a local increased concentration of lipids, appearing as a focal area of increased fluorescence intensity (hot spot) in the fluorescence image, is related to buckling and folding of the lipid layer thereby highly influencing the microbubble acoustic behavior. To test this hypothesis, the lipid microbubble coating was fluorescently labeled. The vibration of the microbubble (n= 177; 2.3-10.3 μm in diameter) upon insonification at an ultrasound frequency of 0.5 or 1 MHz at 25 or 50 kPa acoustic pressure was recorded with the UPMC Cam, an ultra-high-speed fluorescence camera, operated at ∼4-5 million frames per second. During short tone-burst excitation, hot spots on the microbubble coating occurred at relative vibration amplitudes > 0.3 irrespective of frequency and acoustic pressure. Around resonance, the majority of the microbubbles formed hot spots. When the microbubble also deflated acoustically, hot spot formation was likely irreversible. Although compression-only behavior (defined as substantially more microbubble compression than expansion) and subharmonic responses were observed in those microbubbles that formed hot spots, both phenomena were also found in microbubbles that did not form hot spots during insonification. In conclusion, this study reveals hot spot formation of the lipid monolayer in the microbubble's compression phase. However, our experimental results show that there is no direct relationship between hot spot formation of the lipid coating and microbubble acoustic behaviors such as compression-only and the generation of a subharmonic response. Hence, our hypothesis that hot spots are related to acoustic buckling could not be verified. ...
Journal article (2017) - Guillaume Lajoinie, Jeong Yu Lee, Joshua Owen, Pieter Kruizinga, Nico De Jong, Gijs Van Soest, Eleanor Stride, Michel Versluis
Photoacoustic (PA) imaging offers several attractive features as a biomedical imaging modality, including excellent spatial resolution and functional information such as tissue oxygenation. A key limitation, however, is the contrast to noise ratio that can be obtained from tissue depths greater than 1-2 mm. Microbubbles coated with an optically absorbing shell have been proposed as a possible contrast agent for PA imaging, offering greater signal amplification and improved biocompatibility compared to metallic nanoparticles. A theoretical description of the dynamics of a coated microbubble subject to laser irradiation has been developed previously. The aim of this study was to test the predictions of the model. Two different types of oil-coated microbubbles were fabricated and then exposed to both pulsed and continuous wave (CW) laser irradiation. Their response was characterized using ultra high-speed imaging. Although there was considerable variability across the population, good agreement was found between the experimental results and theoretical predictions in terms of the frequency and amplitude of microbubble oscillation following pulsed excitation. Under CW irradiation, highly nonlinear behavior was observed which may be of considerable interest for developing different PA imaging techniques with greatly improved contrast enhancement. ...
Journal article (2017) - Guillaume Lajoinie, Erik Linnartz, Pieter Kruizinga, Nico De Jong, Eleanor Stride, Gijs Van Soest, Michel Versluis
Microbubbles are used to enhance the contrast in ultrasound imaging. When coated with an optically absorbing material, these bubbles can also provide contrast in photoacoustic imaging. This multimodal aspect is of pronounced interest to the field of medical imaging. The aim of this paper is to provide a theoretical framework to describe the physical phenomena underlying the photoacoustic response. This article presents a model for a spherical gas microbubble suspended in an aqueous environment and coated with an oil layer containing an optically absorbing dye. The model includes heat transfer between the gas core and the surrounding liquids. This framework is suitable for the investigation of both continuous wave and pulsed laser excitation. This work utilizes a combination of finite difference simulations and numerical integration to determine the dependancy on the physical properties, including composition and thickness of the oil layer on the microbubble response. A normalization scheme for a linearized version of the model was derived to facilitate comparison with experimental measurements. The results show that viscosity and thickness of the oil layer determine whether or not microbubble resonance can be excited. This work also examines the use of non-sinusoidal excitation to promote harmonic imaging techniques to further improve the imaging sensitivity. ...
Journal article (2016) - Ying Luan, Guillaume Renaud, Nico De Jong, Jason L. Raymond, Tim Segers, Guillaume Lajoinie, Robert Beurskens, Frits Mastik, Tom J A Kokhuis, Antonius F W Van Der Steen, Michel Versluis
In this study we present a combined optical sizing and acoustical characterization technique for the study of the dynamics of single freely-floating ultrasound contrast agent microbubbles exposed to long burst ultrasound excitations up to the milliseconds range. A co-axial flow device was used to position individual microbubbles on a streamline within the confocal region of three ultrasound transducers and a high-resolution microscope objective. Bright-field images of microbubbles passing through the confocal region were captured using a high-speed camera synchronized to the acoustical data acquisition to assess the microbubble response to a 1-MHz ultrasound burst. Nonlinear bubble vibrations were identified at a driving pressure as low as 50 kPa. The results demonstrate good agreement with numerical simulations based on the shell-buckling model proposed by Marmottant et al. [J. Acoust. Soc. Am. 118, 3499-3505 (2005)]. The system demonstrates the potential for a high-throughput in vitro characterization of individual microbubbles. ...
Journal article (2016) - Tim Segers, Nico De Jong, Michel Versluis
The sensitivity and efficiency in contrast-enhanced ultrasound imaging and therapy can potentially be increased by the use of resonant monodisperse bubbles. However, bubbles of the same size may respond differently to ultrasound due to differences in their phospholipid shell. In an acoustic bubble sorting chip, resonant bubbles can be separated from the polydisperse agent. Here, a sample of acoustically sorted bubbles is characterized by measuring scattering and attenuation simultaneously using narrowband acoustic pulses at peak negative pressures of 10, 25, and 50 kPa over a 0.7-5.5 MHz frequency range. A second sample is characterized by attenuation measurements at acoustic pressures ranging from 5 to 75 kPa in steps of 2.5 kPa. Scattering and attenuation coefficients were modeled by integration over the pressure and frequency dependent response of all bubbles located within the non-uniform acoustic characterization beam. For all driving pressures and frequencies employed here, the coefficients could be modeled using a single and unique set of shell parameters confirming that acoustically sorted bubbles provide a uniform acoustic response. Moreover, it is shown that it is crucial to include the pressure distribution of the acoustic characterization beam in the modeling to accurately determine shell parameters of non-linearly oscillating bubbles. ...
Journal article (2016) - Tim Segers, Leonie De Rond, Nico De Jong, Mark Borden, Michel Versluis
Monodisperse microbubble ultrasound contrast agents may dramatically increase the sensitivity and efficiency in ultrasound imaging and therapy. They can be produced directly in a microfluidic flow-focusing device, but questions remain as to the interfacial chemistry, such as the formation and development of the phospholipid monolayer coating over time. Here, we demonstrate the synthesis of monodisperse bubbles with radii of 2-10 μm at production rates ranging from 104 to 106 bubbles/s. All bubbles were found to dissolve to a stable final radius 2.55 times smaller than their initial radius, independent of the nozzle size and shear rate, indicating that the monolayer self-assembles prior to leaving the nozzle. The corresponding decrease in surface area by a factor 6.6 reveals that lipid molecules are adsorbed to the gas-liquid interface in the disordered expanded state, and they become mechanically compressed by Laplace pressure-driven bubble dissolution to a more ordered condensed state with near zero surface tension. Acoustic characterization of the stabilized microbubbles revealed that their shell stiffness gradually increased from 0.8 to 2.5 N/m with increasing number of insonations through the selective loss of the more soluble lipopolymer molecules. This work therefore demonstrates high-throughput production of clinically relevant monodisperse contrast microbubbles with excellent control over phospholipid monolayer elasticity and microbubble resonance. ...
Journal article (2012) - Erik C. Gelderblom, Hendrik J. Vos, Frits Mastik, Telli Faez, Ying Luan, Tom J. A. Kokhuis, Antonius F. W. van der Steen, Detlef Lohse, Nico de Jong, Michel Versluis
The Brandaris 128 ultra-high-speed imaging facility has been updated over the last 10 years through modifications made to the camera’s hardware and software. At its introduction the camera was able to record 6 sequences of 128 images (500×292 pixels) at a maximum frame rate of 25 Mfps. The segmented mode of the camera was revised to allow for subdivision of the 128 image sensors intoarbitrary segments (1–128) with an inter-segment time of 17 μs. Furthermore, a region of interest can be selected to increase the number of recordings within a single run of the camera from 6 up to 125.By extending the imaging system with a laser-induced fluorescence setup, time-resolved ultra-highspeed fluorescence imaging of microscopic objects has been enabled. Minor updates to the systemare also reported here. © 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4758783] ...