The accurate determination of the transfer function of ultrasound transducers is important for their design and operational performance. However, conventional methods for quantifying the transfer function, such as hydrophone measurements, radiation force balance, and pulse-ech ...
GHz half wavelength contact acoustic microscopy (HaWaCAM)
A feasibility study
Common clamp-on ultrasonic flow meters consist of two single-element transducers placed on the pipe wall. Flow speed is measured noninvasively, i.e., without interrupting the flow and without perforating the pipe wall, which also minimizes safety risks and avoids pressure drop ...
In recent years, several fitting techniques have been presented to reconstruct the parameters of a plate from its Lamb wave dispersion curves. Published studies show that these techniques can yield high accuracy results and have the potential of reconstructing several paramete ...
Coatings with dynamic surface structures are appealing to many applications like haptics and soft robotics. Restrictively, the speed of the surface dynamics in these coatings is often limited to frequencies below 1 kHz, which makes them unsuitable for applications like acousti ...
Tapering of the interventricular septum can affect ultrasound shear wave elastography
An in vitro and in silico study
Shear wave elastography (SWE) has the potential to determine cardiac tissue stiffness from non-invasive shear wave speed measurements, important, e.g., for predicting heart failure. Previous studies showed that waves traveling in the interventricular septum (IVS) may display L ...
Current ultrasonic clamp-on flow meters consist of a pair of single-element transducers that are carefully positioned before use. This positioning process consists of manually finding the distance between the transducer elements, along the pipe axis, for which maximum signal-t ...
Acoustic wave propagation in ultrasonic flow measurements is typically assumed to be linear and reciprocal. However, if the transmitting transducer generates a sufficiently high pressure, nonlinear wave propagation effects become significant. In flow measurements, this would t ...
Towards a calibration-free ultrasonic clamp-on flow meter: Pipe geometry measurements using matrix arrays
Pipe geometry measurements using matrix arrays
In Subsurface Scanning Probe Microscopy (SSPM), Atomic Force Microscopy (AFM) is combined with ultrasound. The AFM cantilever is used as a receiver. At low frequencies (O(MHz)) the method can be used to measure the stiffness contrast in a sample and at high frequencies (O(GHz) ...
In Subsurface Scanning Probe Microscopy (SSPM), Atomic Force Microscopy (AFM) is combined with ultrasound. The AFM cantilever is used as a receiver. At low frequencies (O(MHz)) the method can be used to measure the stiffness contrast in a sample and at high frequencies (O(GHz) ...
Both in design and production of nanoparticles and nanocomposites it is of vital importance to have information about their size and concentration. During the formation of nanoparticles, real-time monitoring of particle size and concentration during bottom-up synthesis in liqu ...