Lipid-core atherosclerotic plaques are associated with disease progression, procedural complications, and cardiac events. Coronary plaque lipid can be quantified in optical coherence tomography (OCT) pullbacks by measurement of lipid arcs and lipid lengths; parameters frequently ...
Intravascular ultrasound is an imaging modality used to visualize atherosclerosis from within the inner lumen of human arteries. Complex lesions like chronic total occlusions require forward-looking intravascular ultrasound (FL-IVUS), instead of the conventional side-looking geom ...

Contour segmentation of the intima, media, and adventitia layers in intracoronary OCT images

Application to fully automatic detection of healthy wall regions

Purpose: Quantitative and automatic analysis of intracoronary optical coherence tomography images is useful and time-saving to assess cardiovascular risk in the clinical arena. Methods: First, the interfaces of the intima, media, and adventitia layers are segmented, by means of a ...
In the field of vascular interventions, forward-looking intravascular ultrasound transducers (FL-IVUS) are needed for better visualization of complex lesions, such as chronic total occlusions. In this work, we propose a strategy for 3D imaging using a single-element transducer an ...
In the field of vascular interventions, forward-looking intravascular ultrasound transducers (FL-IVUS) are needed for better visualization of complex lesions, such as chronic total occlusions. In this work, we propose a strategy for 3D imaging using a single-element transducer an ...
Significance: Spectroscopic analysis of optical coherence tomography (OCT) data can yield added information about the sample's chemical composition, along with high-resolution images. Typical commercial OCT systems operate at wavelengths that may not be optimal for identifying li ...
Background and aims: Lipids play an important role in atherosclerotic plaque development and are interesting candidate predictive biomarkers. However, the link between circulating lipids, accumulating lipids in the vessel wall, and plaque destabilization processes in humans remai ...
This paper presents an area- and power-efficient application-specified integrated circuit (ASIC) for 3-D forward-looking intravascular ultrasound imaging. The ASIC is intended to be mounted at the tip of a catheter, and has a circular active area with a diameter of 1.5 mm on the ...
Lipid deposition can be assessed with combined intravascular photoacoustic/ultrasound (IVPA/US) imaging. To date, the clinical translation of IVPA/US imaging has been stalled by a low imaging speed and catheter complexity. In this paper, we demonstrate imaging of lipid targets in ...
Due to the shortage of kidneys donated for transplantation, surgeons are forced to use the organs with an elevated risk of poor function or even failure. Although the existing methods for pre-transplant quality evaluation have been validated over decades in population cohort stud ...
Coronary atherosclerosis is caused by plaque build-up, with lipids playing a pivotal role in its progression. However, lipid composition and distribution within coronary atherosclerosis remain unknown. This study aims to characterize lipids and investigate differences in lipid co ...
The carotid artery (CA) is central to cardiovascular research, because of the clinical relevance of CA plaques as culprits of stroke and the accessibility of the CA for cardiovascular screening. The viscoelastic state of this artery, essential for clinical evaluation, can be asse ...
The identification of unstable atherosclerotic plaques in the coronary arteries is emerging as an important tool for guiding percutaneous coronary interventions and may enable preventive treatment of such plaques in the future. Assessment of plaque stability requires imaging of b ...
This paper presents a front-end ASIC for forward-looking intravascular ultrasound (IVUS) imaging. The ASIC is intended to be mounted at the tip of a catheter and can interface a total of 80 piezo-electric transducer elements with an imaging systems using only 4 cables, thus signi ...
This paper presents a front-end ASIC for forward-looking intravascular ultrasound (IVUS) imaging. The ASIC is intended to be mounted at the tip of a catheter and can interface a total of 80 piezo-electric transducer elements with an imaging systems using only 4 cables, thus signi ...
The size of the features, and their relative distance to the probe, vary a lot in the intracardiac echocardiography application thus challenging the design of the probe. Therefore it may be beneficial to design a versatile probe which can produce both a large image to provide ove ...
The size of the features, and their relative distance to the probe, vary a lot in the intracardiac echocardiography application thus challenging the design of the probe. Therefore it may be beneficial to design a versatile probe which can produce both a large image to provide ove ...
A dual frequency probe using a multi-layer piezoelectric material is proposed for simultaneous ultrasound and photoacoustic imaging of the carotid artery with a high resolution ultrasound and a high sensitivity photoacoustic image. The probe consists of lead zirconate titanate (P ...
A dual frequency probe using a multi-layer piezoelectric material is proposed for simultaneous ultrasound and photoacoustic imaging of the carotid artery with a high resolution ultrasound and a high sensitivity photoacoustic image. The probe consists of lead zirconate titanate (P ...