Journal article (2025) - Jeonghwan Park, Hak Young Ahn, Minho Seong, Taehoon Kim, Yulin Zhou, Yameng Xu, Jaehee Lee, Ritika Raj Menghani, Elena Aprea, More authors...
Conventional strategies for the management of acute pain have significant limitations. Pharmaceutical approaches carry risks for addiction and misuse. Standard implantable devices require secondary surgeries for removal and physical tethers to external systems for power and control. Recent work on bioresorbable electrical stimulators overcomes certain of these drawbacks, but existing versions still depend on transcutaneous leads. Here, we introduce a platform that employs thermal mechanisms for nerve block to bypass some of these limitations. The system integrates both a Joule heating element and a resistive temperature sensor in a soft cuff structure as a nerve interface, in which most of the materials are bioresorbable over a clinically relevant timeframe. This design enables precise control of nerve temperature within a safe range (≤45°C) for effective nerve block through a feedback-guided strategy that continuously monitors temperature and adjusts current in real time. Options for wireless power delivery eliminate the need for external interfaces. Small animal model studies confirm the reversible and non-invasive operation of this system. The results demonstrate effective suppression of compound nerve action potentials in response to thermal stimulation, with recovery of nerve conduction upon cooling. These findings highlight the potential of this platform as a safe and effective solution to acute pain management. ...
This article presents a 4096-element ultrasound probe for high volume-rate (HVR) cardiovascular imaging. The probe consists of two application-specific integrated circuits (ASICs), each of which interfaces with a 2048-element monolithically-integrated capacitive micro-machined ultrasound transducer (CMUT) array. The probe can image a 60° × 60° × 10-cm volume at 2000 volumes/s, the highest volume-rate with in-probe channel-count reduction reported to date. It uses 2 × 2 delay-and-sum micro-beamforming (μBF) and 2× time-division multiplexing (TDM) to achieve an 8× receive (RX) channel-count reduction. Equalization, trained using a pseudorandom bit-sequence generated on the chip, reduces TDM-induced crosstalk by 10 dB, enabling power-efficient scaling of the cable drivers. The ASICs also implement a novel transmit (TX) beamformer (BF) that operates as a programmable digital pipeline, which enables steering of arbitrary pulse-density modulated (PDM) waveforms. The TX BF drives element-level 65 V unipolar pulsers, which in turn drive the CMUT array. Both the TX BF and RX μBF are programmed with shift-registers (SRs) that can either be programmed in a row-column fashion for fast upload times, or daisy-chain fashion for a higher flexibility. The layout of the ASICs is matched to the 365-μm-pitch monolithically-integrated CMUT array. While operating, the RX and logic power consumption per element is 0.85 and 0.10 mW, respectively. TX power consumption is highly waveform dependent, but is nominally 0.34 mW. Compared to the prior art, the probe has the highest volume rate, and features among the largest imaging arrays (both in terms of element-count and aperture) with a high flexibility in defining the TX waveform. These properties make it a suitable option for applications requiring HVR imaging of a large region of interest. ...
IN [1], there is a mistake in the timing diagram shown in Fig. 6. Switches S 1-S 4 are skipping some of the samples and the rate at which they are operating implies a TDM rate of 10 MHz, whereas (as described in [1]) this should be 20 MHz. In the updated Fig. 6, S 1-S 4 have been updated and a minor change has been made to the timing shown for switches Q1 and Q2, such that the correct TDM rate is indicated and no sample provided to the S/H stage via N1-N4 is skipped in the diagram. (Figure presented). ...
Conference paper (2022) - Djalma Simoes Dos Santos, Fabian Fool, Taehoon Kim, Emile Noothout, Nuriel Rozsa, Hendrik J. Vos, Johan G. Bosch, Michiel A.P. Pertijs, Martin D. Verweij, Nico De Jona
Over the past decades, ultrasound imaging has made considerable progress based on the advancement of imaging systems as well as transducer technology. With the need for advanced transducer arrays with complex designs and technical requirements, there is also a need for suitable tools to characterize such transducers. However, despite the importance of acoustic characterization to assess the performance of novel transducer arrays, the characterization process of highly complex transducers might involve various manual steps, which are laborious, time-consuming, and subject to errors. These factors can hinder the full characterization of a prototype transducer, leading to an under-representation or inadequate evaluation. To come to an extensive, high-quality evaluation of a prototype transducer, the acoustic characterization of each transducer element is indispensable in both transmit and receive operations. In this paper, we propose a pipeline to automatically perform the acoustic characterization of a matrix transducer using a research imaging system. The performance of the pipeline is tested on a prototype matrix transducer consisting of 960 elements. The results show that the proposed pipeline is capable of performing the complete acoustic characterization of a high-element count transducer in a fast and convenient way. ...
This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) directly integrated with an array of 12 × 80 piezoelectric transducer elements to enable next-generation ultrasound probes for 3D carotid artery imaging. The ASIC, implemented in a 0.18 µm high-voltage Bipolar-CMOS-DMOS (HV BCD) process, adopted a programmable switch matrix that allowed selected transducer elements in each row to be connected to a transmit and receive channel of an imaging system. This made the probe operate like an electronically translatable linear array, allowing large-aperture matrix arrays to be interfaced with a manageable number of system channels. This paper presents a second-generation ASIC that employed an improved switch design to minimize clock feedthrough and charge-injection effects of high-voltage metal–oxide–semiconductor field-effect transistors (HV MOSFETs), which in the first-generation ASIC caused parasitic transmis-sions and associated imaging artifacts. The proposed switch controller, implemented with cascaded non-overlapping clock generators, generated control signals with improved timing to mitigate the effects of these non-idealities. Both simulation results and electrical measurements showed a 20 dB reduction of the switching artifacts. In addition, an acoustic pulse-echo measurement successfully demonstrated a 20 dB reduction of imaging artifacts. ...
Over the past decades, real-time three-dimensional (3D) medical ultrasound has attracted much attention since it enables clinicians to diagnose more accurately. This calls for ultrasound matrix transducers with a large number of elements, which can be interfaced with an application-specific integrated circuit (ASIC) for data reduction. An important aspect of the design of such a transducer is the geometry of each element, since it affects the mode of vibration and, consequently, the efficiency of the transducer. In this paper, we experimentally investigate the effect of subdicing on a piezoelectric (PZT) transducer. We fabricate and acoustically characterize a prototype PZT matrix transducer built on top of ASICs. The prototype transducer contains subdiced and non-subdiced elements, whose performance can be directly compared under the same conditions. Measurement results show that subdiced elements have a better performance compared to non-subdiced ones. Subdicing increases the peak pressure by 25%, raises the bandwidth by 10% and reduces the ringing time by 25%. ...