Circular Image

U. Staufer

info

Please Note

37 records found

Journal article (2026) - P.F.J. van Altena, Lucía Castillo Ransanz, R.H. Guis, Giulia Bergamaschi, Nanne J. Paauw, U. Staufer, Vivi M. Heine, A. Accardo
During neural development, cells generate and respond to mechanical forces within their microenvironment while they migrate and differentiate. These forces are central to the development of the human brain, as they are transduced into intracellular signals that regulate key neurobiological processes and may be involved in pathological processes. However, measurement of such forces in the nanonewton (nN) range within a three-dimensional (3D) microenvironment remains technically challenging and computationally intensive. Here, we present a solution to this challenge, based on elastomeric 3D microstructures fabricated via two-photon polymerization (2PP) and a tailored wet-etching process. The resulting free-standing beam architectures enable the quantification of nN forces exerted by pluripotent stem cell-derived neuroepithelial progenitor cells. We characterized the morphology of the cells and the forces they exerted using live-cell confocal imaging microscopy, scanning electron microscopy (SEM), supported by an in-house routine for intensity-based deflection measurements with sub-pixel resolution, and atomic force microscopy (AFM). Using this platform, we precisely quantified neuronal traction forces down to 1.2 nN from both healthy neural cells and those carrying a TSC2 gene mutation linked to tuberous sclerosis complex (TSC). The proposed elastomeric microenvironment paves the way for investigating cytoskeletal mechanics, neuromechanobiology in 3D, and for developing in vitro disease treatment models. ...
Journal article (2026) - L. V. Fricke, N. Wansink, M. Rosso, G. van Ewijk, M.P. Smak, P. Belardinelli, U. Staufer, F. Alijani
Waterborne polymer coatings are increasingly used as sustainable alternatives to solvent-borne systems, but their long-term durability remains a challenge. Elucidating their degradation mechanism at the nanoscale, where damage first emerges, is essential for delivering more durable waterborne coatings. Here, we use intermodulation atomic force microscopy (ImAFM) to investigate the nanoscale origins of degradation in an accelerated weathered waterborne acrylate coating. Our measurements reveal a progressive, three-stage degradation pathway induced by accelerated weathering. In the first stage, the coating stiffens as a result of physical aging and (photo-)chemically induced degradation. Subsequently, former acrylate particles re-emerge and become surrounded by regions of increased damping and reduced stiffness. Continued weathering eventually gives rise to pronounced viscoelastic heterogeneity. To support these observations, we performed both bulk and nanoscale dynamic mechanical analysis measurements on accelerated weathered samples. These measurements reveal increased storage modulus and damping, consistent with the nanoscale evolution observed by ImAFM. Together, these results identify the mechanical changes that precede macroscopic embrittlement and demonstrate that durability limitations in waterborne acrylate coatings are strongly linked to the development of localized viscoelastic heterogeneity at the nanoscale. ...
A significant challenge in developing meta-biomaterials is the effective decoupling of their intrinsically intertwined mechanical properties (e.g., elastic and shear moduli, Poisson’s ratio, and anisotropy level), morphometric properties (e.g., relative mass density, pore size, and surface-to-volume ratio), and mass-transport properties (e.g., permeability). To address this challenge, we introduce a general framework for decoupling mechanical and morphometric properties in non-stochastic, three-dimensional meta-biomaterials. We first derived explicit geometrical relationships to determine the upper and lower bounds of the input geometrical parameters while ensuring relevance to in vitro biological conditions. Using a high-throughput numerical homogenization method (44,837 simulations) combined with systematic multi-objective optimization, we successfully decoupled Poisson’s ratio and relative mass density from all other properties, with average deviations below ~14%. The optimized meta-biomaterials were additively manufactured at the macro- and microscales using PolyJet 3D printing and two-photon polymerization, respectively, and experimentally validated in terms of effective elastic modulus, Poisson’s ratio, and permeability. The established decoupling framework provides a promising route for advancing tissue engineering and cell mechanobiology studies by enabling independent investigation of the effects of individual scaffold properties on cell behavior. ...
Journal article (2026) - Maarten Jankie, Thomas Hackl, Georg Schitter, Urs Staufer
As a result of current trends in miniaturisation and the need for faster electronic circuits, integrated circuit (IC) design has become more complex. Closely packed conductors carrying radiofrequency (RF) signals are subjected to parasitic coupling, complicating the IC design and validation. Prototyping of such devices is supported by contact probes that make an ohmic connection to contact pads. These pads take up valuable space and may interfere with the design. Alternatively, near-field probing techniques, that utilise capacitive and inductive coupling, have been employed for local RF voltage and current characterisation. In this research, such a near-field probe is developed through a multiscale 3D-printing process. It contains a miniaturised conductive loop, enclosing an area of 12.5µm2, and a conductive tip with an apex radius of 100nm. A model-based approach, that makes use of the discrepancy between parasitic long-range, and local short-range contributions to the measurement signal, is expanded to conduct both RF voltage and current measurements with increased spatial resolution. With this approach, combined contactless RF-voltage and RF-current measurements were executed demonstrating a measurement bandwidth from 1 to 23GHz. Capacitively coupled RF-voltage measurements achieved a spatial resolution of 8µm, while the spatial resolution of inductively coupled current measurements was only simulated. The simulation shows an expected spatial resolution of 3µm. ...
Journal article (2026) - L.V. Fricke, N. Wansink, Michel Rosso, U. Staufer, Pierpaolo Belardinelli, F. Alijani
Atomic force microscopy (AFM) has evolved into a powerful instrument for examining material properties at the nanoscale. However, quantifying viscoelasticity using AFM remains a challenging task, since existing methods face sensitivity issues when it comes to the separation of viscous and elastic material properties. Here, a method is proposed that utilizes the nonlinear dynamic response of the AFM cantilever to effectively disentangle and independently quantify the dissipative and conservative parts of the tip-sample interaction force. Through measurements on one and two component solvent-borne coatings, it is demonstrated that the strength of the nonlinearity of AFM cantilever motion is predominantly determined by the elasticity of the sample, whereas the detuned frequency of the nonlinear resonance is contingent on the viscosity. The sensitivity of the quantified values is discussed by comparing the results to those of established multi-frequency AFM measurements, showing good agreement. These findings underscore the effectiveness of nonlinear dynamic AFM for deciphering viscous and elastic material properties, potentially accelerating the development cycles of polymeric coating materials. ...
Cryogenic electron microscopy (cryoEM) has become an indispensable technique for determining the structures of isolated biological macromolecules and imaging biomolecular structures within cells. While thin films of frozen-hydrated macromolecule suspensions can be directly prepared and imaged, these molecules must be extracted from their cellular context using existing sample preparation methods. On the other hand, cellular specimens preserve the native context, but the region of interest must be sectioned or subjected to focused ion-beam milling at cryogenic temperatures to achieve the necessary thickness for transmission electron imaging. Currently, no method exists for targeted cytoplasmic extraction of a subcellular volume from individual cells for direct vitrification and cryoEM imaging. In this study, a method is presented that addresses this gap. A system has developed that utilizes a force-sensitive microfluidic cantilever pipette to aspirate and dispense sample volumes as small as 204 fL onto conventional cryoEM sample supports, maintained at the dew point. This is followed by automatic vitrification for cryoEM imaging. Coupled with a fluorescence microscope, this setup allows for the extraction of a targeted subcellular volume from an individual cell and subsequent dispensing of the aspirated content onto an electron microscopy grid. A proof-of-concept is demonstrated by dispensing femtolitre volumes of the standard cryoEM single-particle sample, tobacco mosaic virus, and performing a subcellular biopsy from a single HeLa cell. Additionally, the challenges of manipulating such small volumes for cryoEM sample preparation are discussed, highlighting the current limitations of this approach and potential solutions for overcoming them. ...
Journal article (2025) - Jie Ji, Jasmine R. Petriglieri, Shanzina Sompa, Per Gerde, Dag Linnarsson, David J. Loftus, Urs Staufer, Erin M. Tranfield, Wim van Westrenen, More authors...
Human exploration of the Moon and Mars will inevitably result in exposure to extraterrestrial dust. We investigated the potential pulmonary toxicity of JSC Mars-1(Martian dust simulant, respirable diameter 1.45 μm) using an advanced multicellular lung mucosa model with dust applied apically to human bronchial epithelial cells cultured at the air-liquid interface, with doses 55, 222, and 890 μg/cm2, PBS (sham). Compared to the sham, medium and high doses of JSC Mars-1 increased necrosis-related gene HMGB1 expression. The cellular total reactive oxygen species (ROS) levels increased in a dose-dependent manner. The expression of antioxidant-related genes, HMOX-1 and SOD3, increased at all dose levels. Interleukin-6 (IL-6) protein and gene expression increased, and tumor necrosis factor alpha (TNF-α) after high dose. CXCL8 mRNA was elevated at medium and high doses. TLR4 surface and gene expression decreased at medium and high doses. JSC Mars-1 dust increased cytotoxicity, oxidative stress, and immune responses suggesting potential pulmonary toxic effects, providing insight to molecular mechanisms behind potential adverse respiratory effects. ...
Journal article (2025) - Francesco La Malfa, Isabella A. van Hulst, Ferry Ossendorp, Urs Staufer, Koen van der Maaden
Objective: Microneedle technologies have emerged as a promising approach to improve intradermal drug delivery. This study presents a comprehensive workflow for fabricating polymeric microneedle arrays utilising ultrahigh-resolution 3-dimensional (3D) printing and silicone mould fabrication. Methods: In this work, an extensive toolbox with over 75 distinct microneedle designs was created and sequentially fabricated from acryl using our workflow based on ultrahigh-resolution 3D printing. Results: The microneedle design parameters included obelisk and cone-like shapes, various lengths, base and tip diameters, and different densities. We systematically assessed the optimal design parameters for effective penetration of ex vivo human skin explants. Conclusion: Our workflow, combined with application in an ex vivo human skin model, allows systematic comparison of multiple microneedle design parameters for efficacy. This work demonstrates the potential of this systematic modelling and ultrahigh-resolution 3D printing approach to optimize microneedles for intradermal biomedical applications, including therapeutic cancer vaccination. ...
The Poisson's ratio and elastic modulus are two parameters determining the elastic behavior of biomaterials. While the effects of elastic modulus on the cell response is widely studied, very little is known regarding the effects of the Poisson's ratio. The micro-architecture of meta-biomaterials determines not only the Poisson's ratio but also several other parameters that also influence cell response, such as porosity, pore size, and effective elastic modulus. It is, therefore, very challenging to isolate the effects of the Poisson's ratio from those of other micro-architectural parameters. Here, we computationally design meta-biomaterials with controlled Poisson's ratios, ranging between -0.74 and +0.74, while maintaining consistent porosity, pore size, and effective elastic modulus. The 3D meta-biomaterials were additively manufactured at the micro-scale using two-photon polymerization (2PP), and were mechanically evaluated at the meso‑scale. The response of murine preosteoblasts to these meta-biomaterials was then studied using in vitro cell culture models. Meta-biomaterials with positive Poisson's ratios resulted in higher metabolic activity than those with negative values. The cells could attach and infiltrate all meta-biomaterials from the bottom to the top, fully covering the scaffolds after 17 days of culture. Interestingly, the meta-biomaterials exhibited different cell-induced deformations (e.g., shrinkage or local bending) as observed via scanning electron microscopy. The outcomes of osteogenic differentiation (i.e., Runx2 immunofluorescent staining) and matrix mineralization (i.e., Alizarin red staining) assays indicated the significant potential impact of these meta-biomaterials in the field of bone tissue engineering, paving the way for the development of advanced bone meta-implants. Statement of significance: We studied the influence of Poisson's ratio on bone cell response in meta-biomaterials. While elastic modulus effects are well-studied, the impact of Poisson's ratio, especially negative values found in architected biomaterials, remains largely unexplored. The complexity arises from intertwined micro-architectural parameters, such as porosity and elastic modulus, making it challenging to isolate the Poisson's ratio. To overcome this limitation, this study employed rational computational design to create meta-biomaterials with controlled Poisson's ratios, alongside consistent effective elastic modulus, porosity, and pore size. The study reveals that two-photon polymerized 3D meta-biomaterials with positive Poisson's ratios displayed higher metabolic activity, while all the developed meta-biomaterials supported osteogenic differentiation of preosteoblasts as well as matrix mineralization. The outcomes pave the way for the development of advanced 3D bone tissue models and meta-implants. ...
Review (2024) - Cristina Richie, Pilar Garcia-Gomez, Hok Bing Thio , A.Y. Rwei, C. Joo, U. Staufer, D.G. Muratore, Massimo Mastrangeli, I.C. Dedoussi, More authors...
Climate and justice are interconnected. However, simply raising ethical issues associated with the links between climate change, technology, and health is insufficient. Rather, policies and practices need to consider ethics ahead of time. If it is only added “after the fact,” policy will be less efficient and opportunities for carbon minimization will be lost. This will require the cooperation of people at many levels and can be guided by two essential ethical principles: distributive justice and environmental sustainability. ...
Mechanical and morphological design parameters, such as stiffness or porosity, play important roles in creating orthopedic implants and bone substitutes. However, we have only a limited understanding of how the microarchitecture of porous scaffolds contributes to bone regeneration. Meta-biomaterials are increasingly used to precisely engineer the internal geometry of porous scaffolds and independently tailor their mechanical properties (e.g., stiffness and Poisson's ratio). This is motivated by the rare or unprecedented properties of meta-biomaterials, such as negative Poisson's ratios (i.e., auxeticity). It is, however, not clear how these unusual properties can modulate the interactions of meta-biomaterials with living cells and whether they can facilitate bone tissue engineering under static and dynamic cell culture and mechanical loading conditions. Here, we review the recent studies investigating the effects of the Poisson's ratio on the performance of meta-biomaterials with an emphasis on the relevant mechanobiological aspects. We also highlight the state-of-the-art additive manufacturing techniques employed to create meta-biomaterials, particularly at the micrometer scale. Finally, we provide future perspectives, particularly for the design of the next generation of meta-biomaterials featuring dynamic properties (e.g., those made through 4D printing). ...
Quantifying the nanomechanical properties of soft-matter using multi-frequency atomic force microscopy (AFM) is crucial for studying the performance of polymers, ultra-thin coatings, and biological systems. Such characterization processes often make use of cantilever's spectral components to discern nanomechanical properties within a multi-parameter optimization problem. This could inadvertently lead to an over-determined parameter estimation with no clear relation between the identified parameters and their influence on the experimental data. In this work, we explore the sensitivity of viscoelastic characterization in polymeric samples to the experimental observables of multi-frequency intermodulation AFM. By performing simulations and experiments we show that surface viscoelasticity has negligible effect on the experimental data and can lead to inconsistent and often non-physical identified parameters. Our analysis reveals that this lack of influence of the surface parameters relates to a vanishing gradient and non-convexity while minimizing the objective function. By removing the surface dependency from the model, we show that the characterization of bulk properties can be achieved with ease and without any ambiguity. Our work sheds light on the sensitivity issues that can be faced when optimizing for a large number of parameters and observables in AFM operation, and calls for the development of new viscoelastic models at the nanoscale and improved computational methodologies for nanoscale mapping of viscoelasticity using AFM. ...
Journal article (2022) - A. Chandrashekar, P. Belardinelli, M.A. Bessa, U. Staufer, F. Alijani
Dynamic atomic force microscopy (AFM) is a key platform that enables topological and nanomechanical characterization of novel materials. This is achieved by linking the nanoscale forces that exist between the AFM tip and the sample to specific mathematical functions through modeling. However, the main challenge in dynamic AFM is to quantify these nanoscale forces without the use of complex models that are routinely used to explain the physics of tip–sample interaction. Here, we make use of machine learning and data science to characterize tip–sample forces purely from experimental data with sub-microsecond resolution. Our machine learning approach is first trained on standard AFM models and then showcased experimentally on a polymer blend of polystyrene (PS) and low density polyethylene (LDPE) sample. Using this algorithm we probe the complex physics of tip–sample contact in polymers, estimate elasticity, and provide insight into energy dissipation during contact. Our study opens a new route in dynamic AFM characterization where machine learning can be combined with experimental methodologies to probe transient processes involved in phase transformation as well as complex chemical and biological phenomena in real-time. ...
Conference paper (2022) - Philippa Kate Andrew, Allan Raudsepp, Volker Nock, D. Fan, Martin A.K. Williams, U. Staufer, Ebubekir Avci
Optical micromachines have the potential to improve the capabilities of optical tweezers by amplifying forces and allowing for indirect handling and probing of specimens. However, systematic design and testing of micromachine performance is still an emerging field. In this work we have designed and tested an unsupported microlever, suitable for general-purpose optical tweezer studies, that demonstrates stable trapping performance and repeatable doubling of applied forces. Stable trapping was ensured by analysing images to monitor focus shift when levers oscillated repeatedly, before the best-performing design was selected for force amplification. This study also shows that direct measurement of trap stiffness using the equipartition theorem appears to be a valid method for measuring applied forces on the spherical handles of microlevers. ...
Journal article (2021) - PHILIPPA KATE ANDREW, ALLAN RAUDSEPP, DANIEL FAN, URS STAUFER, MARTIN A.K. WILLIAMS, EBUBEKIR AVCI
Optical microrobotics is an emerging field that has the potential to improve upon current optical tweezer studies through avenues such as limiting the exposure of biological molecules of interest to laser radiation and overcoming the current limitations of low forces and unwanted interactions between nearby optical traps. However, optical microrobotics has been historically limited to rigid, single-body end-effectors rather than even simple machines, limiting the tasks that can be performed. Additionally, while multi-body machines such as microlevers exist in the literature, they have not yet been successfully demonstrated as tools for biological studies, such as molecule stretching. In this work we have taken a step towards moving the field forward by developing two types of microlever, produced using two-photon absorption polymerisation, to perform the first lever-assisted stretches of double-stranded DNA. The aim of the work is to provide a proof of concept for using optical micromachines for single molecule studies. Both styles of microlevers were successfully used to stretch single duplexes of DNA, and the results were analysed with the worm-like chain model to show that they were in good agreement. ...
Journal article (2021) - Abhilash Chandrashekar, Pierpaolo Belardinelli, Stefano Lenci, Urs Staufer, Farbod Alijani
Increasing the signal-to-noise ratio in dynamic atomic force microscopy plays a key role in nanomechanical mapping of materials with atomic resolution. In this work, we develop an experimental procedure for increasing the sensitivity of higher harmonics of an atomic-force-microscope cantilever without modifying the cantilever geometry but instead by utilizing dynamical mode coupling between its flexural modes of vibration. We perform experiments on different cantilevers and samples and observe that via nonlinear resonance frequency tuning we can obtain a frequency range where strong modal interactions lead to 7-fold and 16-fold increases in the sensitivity of the 6th and 17th harmonics while reducing sample indentation. We derive a numerical model that captures the observed physics and confirms that nonlinear mode coupling is the reason for the increase of the amplitude of higher harmonics during tip-sample interactions. ...
Detected kidney stone cases are increasing globally, yet knowledge on the conditions for stone formation is lacking. Experimental approaches mimicking the micro-environmental conditions present in vivo can help sci-entists untangle intertwined physiochemical and biological phenomena leading to kidney stone formation. As crystal nucleation often initiates at liquid-solid interfaces, the interface morphology plays a significant role in the rate of nucleation. Within the nephron, the functional unit of the kidney, four segments can be distinguished that contain different surface morphologies. Particularly, the cells lining these segments contain protrusions in the shape of nanopillars that vary in length, diameter and spacing. Exploiting the opportunities provided by organ- on-a-chip technology, we designed and manufactured a proof-of-principle microfluidic device proposed to in-crease our understanding of the relation between kidney surface morphology and kidney stone crystallization. We used two-photon polymerization to fabricate biocompatible surfaces that mimic the nephron morphologies with materials properties similar to those of biological structures. The fabricated cilia were incorporated in the microfluidic device, which was designed to observe in vitro crystallization of calcium oxalate under flow ...
Journal article (2021) - M. Mariello, T. W.A. Blad, V. M. Mastronardi, F. Madaro, F. Guido, U. Staufer, N. Tolou, M. De Vittorio
There is a high demand for novel flexible micro-devices for energy harvesting from low-frequency and random mechanical sources. The research of new functional designs is required to strategically enhance the performances and to increase the control on mechanical flexibility. In this work we report the fabrication and characterization of bi-stable and statically balanced thin-film piezoelectric transducers based on Aluminum Nitride (AlN). The device consists of a piezoelectric layer sandwiched between two thin Molybdenum electrodes that were deposited on a Kapton substrate by reactive sputtering and patterned by UV lithography. In order to improve the out-of-plane flexibility, the mechanical design is distinguished by a post-buckled flexure that introduces a negative stiffness to compensate the otherwise positive stiffness of the system. The buckling was introduced by a new method, called Package-Induced Preloading (PIP) where the mechanisms are laminated over a package with a geometry extending out-of-plane. The induced buckling resulted in bi-stable and statically balanced mechanisms which demonstrated an enhanced voltage output during a triggered snapping step. A preliminary study shows potential for the statically balanced designs and the PIP method for wind energy harvesting, revealing prospective applications and future improvements for the development of energy harvesters. ...
Fabricating large areas of geometrically complex and precisely controlled topographies is required for the studies of cell behavior on patterned surfaces. Direct laser writing (DLW) is an advanced 3D-fabrication technique, which facilitates the manufacturing of structures within various scales (from a few hundred nanometers to millimeters). However, this method requires improvements in the accuracy and reproducibility of the submicron and nanoscale features that are printed over a large area. Here, we present a scheme to both improve the uniformity of the printed submicron patterns and decrease the printing time. The effects of various processing parameters (e.g., laser power and writing field) on the dimensions and uniformity of submicron pillars as well as on their Young’s modulus and surface wettability were assessed. Decreasing the writing field to 33 × 33 μm2 significantly improved the uniformity of submicron pillars that were printed over an area of 4 mm2 in a single-step process. Preosteoblast cells (MC3T3-E1) were used to assess the cytocompatibility of the used material (IP-L780 resin) with a focus on cell morphology, cell proliferation, cytoskeletal organization, and the elastic modulus of the cells. The cells cultured for 2 days on the submicron pillars showed a polarized shape and a higher Young’s modulus of the area corresponding to the nucleus relative to those cultured on flat surfaces. Taken together, the results of the current study clearly show that the submicron patterns created using DLW are both cytocompatible and could modulate the morphology and mechanical properties of cells. This work paves the way for direct printing of submicron features with controlled Young’s moduli over large areas in a single-step process, which is necessary for systematically studying how such patterns modulate cellular functions. ...
Suspended microfluidic resonators enable detection of fluid density and viscosity with high sensitivity. Here, a two-legged suspended microchannel resonator that probes pico-litres of liquid is presented. The higher resonant modes (flexural and torsional) were explored for increased sensitivity and resolution. Unlike other reported microchannel resonators, this device showed an increase in the quality factor with resonant frequency value. The performance of the resonator was tested by filling the channel with three liquids, one at a time, over a density range of 779 - 1110 Kg/m^3 and a viscosity range of 0.89 - 16.2 mPa.s. The highest resolution obtained was 0.011% change in density. Measurements with torsional mode showed an improvement of about six times in sensitivity and about fifteen times in resolution compared to the first flexural mode. When the empty channel was filled with liquids of different viscosity, the quality factor of the first flexural mode remained overall constant with a variation below 3.3% between the fluids, and confirming the inherent property of suspended microchannel resonators. However, it significantly decreased for second flexural and torsional modes. No noticeable difference was observed in the quality factor between different liquid viscosities for all modes. ...